- Permit details
- Permit number: RES-NEW-26-003664
Project number: R-SF-005600
Work category: Building / Residential / New
Recorded status: Inspection Phase
Reported project value: $198,000
- Original job description and scope
- New construction. single family detached home. 4 bed, 3 bath. Attached garage. Concrete Patio. 2000 SF heated, 504 SF unheated.
- Recorded dates
- Applied: Jun 30, 2026
Intake: Jun 30, 2026
Issued: Jun 30, 2026
Status Date: Jun 30, 2026
- Inspection 1
- Inspection Id: 446859
Type: MS - Mono Slab
Date: Jul 31, 2026, 10:57 AM UTC
Result: Failed
Status: Insp Cancelled
Inspector: Eric Durand
Comments: Failed pending upgrade verification form. Proceed at your own risk.
Request Date: Jul 30, 2026
Scheduled Date: Jul 31, 2026
Inspection Group: RES_BLDG
Inspection Team: Res SFH >175k - Bldg
Inspection Conducted: Yes
- Inspection 2
- Inspection Id: 446863
Type: MS - Mono Slab
Date: Sep 3, 2026, 9:58 AM UTC
Result: Passed
Status: Insp Completed
Inspector: Eric Durand
Comments: Item corrected
Request Date: Sep 2, 2026
Scheduled Date: Sep 3, 2026
Inspection Group: RES_BLDG
Inspection Team: Res SFH >175k - Bldg
Inspection Conducted: Yes
- Inspection 3
- Inspection Id: 446864
Type: SH - Sheathing
Date: Sep 14, 2026, 3:33 PM UTC
Result: Passed
Status: Insp Completed
Inspector: Eric Durand
Comments: Interior concealed spaces only
Request Date: Sep 10, 2026
Scheduled Date: Sep 14, 2026
Inspection Group: RES_BLDG
Inspection Team: Res SFH >175k - Bldg
Inspection Conducted: Yes
- Inspection 4
- Inspection Id: 446861
Type: SH - Sheathing
Date: Sep 22, 2026, 10:30 AM UTC
Result: Passed
Status: Insp Completed
Inspector: Eric Durand
Comments: Exterior sheathing only.
Note: rough trades have not been completed.
Request Date: Sep 21, 2026
Scheduled Date: Sep 22, 2026
Inspection Group: RES_BLDG
Inspection Team: Res SFH >175k - Bldg
Inspection Conducted: Yes
- Inspection 5
- Inspection Id: 446862
Type: FR - Framing
Date: Sep 26, 2026, 11:54 AM UTC
Result: Failed
Status: Insp Cancelled
Inspector: Dustin Nichols
Comments: 1. Seal gaps between garage and living space in floor system. Light can be seen around floor trusses.
2. Seal gap around water line through draft stop under stairs.
3. Level 2 duct chases have not been completed.
4. Could not locate truss layouts. No trusses inspected.
5. Flashing needed at left side communication wires.
Request Date: Sep 23, 2026
Scheduled Date: Sep 24, 2026
Inspection Group: RES_BLDG
Inspection Team: Res SFH >175k - Bldg
Inspection Conducted: Yes
- Inspection 6
- Inspection Id: 446860
Type: FR - Framing
Date: Oct 5, 2026, 1:05 PM UTC
Result: Passed
Status: Insp Completed
Inspector: Eric Durand
Comments: Items corrected
Request Date: Oct 2, 2026
Scheduled Date: Oct 5, 2026
Inspection Group: RES_BLDG
Inspection Team: Res SFH >175k - Bldg
Inspection Conducted: Yes
- Inspection 7
- Inspection Id: 446865
Type: IN - Insulation
Date: Oct 13, 2026, 10:09 AM UTC
Result: Passed
Status: Insp Completed
Inspector: Eric Durand
Request Date: Oct 8, 2026
Scheduled Date: Oct 12, 2026
Inspection Group: RES_BLDG
Inspection Team: Res SFH >175k - Bldg
Inspection Conducted: Yes
- Related record 1
- Permit Number: RES-PLM-26-006863
Url: https://gis.mecklenburgcountync.gov/meck-accela/permit/RES-PLM-26-006863
Relationship: Children; Same Parcel; Same Project
Accela Id: 00000REC2602AVD
Status: Inspection Phase
Permit Type: Residential
Permit Subtype: Plumbing
Permit Application Submitted Date: Jun 30, 2026
Permit Issued Date: Jun 30, 2026
Total Construction Cost: $198,000
Municipality: CHARLOTTE
- Related record 2
- Permit Number: RES-MEC-26-014387
Url: https://gis.mecklenburgcountync.gov/meck-accela/permit/RES-MEC-26-014387
Relationship: Children; Same Parcel; Same Project
Accela Id: 00000REC2602AVB
Status: Inspection Phase
Permit Type: Residential
Permit Subtype: Mechanical
Permit Application Submitted Date: Jun 30, 2026
Permit Issued Date: Jun 30, 2026
Total Construction Cost: $198,000
Municipality: CHARLOTTE
- Related record 3
- Permit Number: RES-ELC-26-017701
Url: https://gis.mecklenburgcountync.gov/meck-accela/permit/RES-ELC-26-017701
Relationship: Children; Same Parcel; Same Project
Accela Id: 00000REC2602AVA
Status: Inspection Phase
Permit Type: Residential
Permit Subtype: Electrical
Permit Application Submitted Date: Jun 30, 2026
Permit Issued Date: Jun 30, 2026
Total Construction Cost: $198,000
Municipality: CHARLOTTE
- GIS Permit Details
- Is Finaled: N
Co Required: YES
Permit Fee Type: Construction
Heated Square Feet: 2000
Unheated Square Feet: 504
Project Name: Wales
Tax Jurisdiction: CHARLOTTE
Usdc Code And Description: 101 - ONE FAMILY DETACHED
Type Of Work: New
Building Construction Cost System: 141876
- Public Permit Details
- Permit Requiring Plan Review: No
Co Required: Yes
Type Of Building: New Bldg
Number Of Units: 1
Issued By: Daniel Nino Aguirre Campis
- Holds
- 1 / Accela Id: 00000REC2602AV9
1 / Permit Number: RES-NEW-26-003664
1 / Permit Status: Inspection Phase
1 / Permit Status Date: Jun 30, 2026
1 / Name: OCC - Land Development Final Site Inspection Hold
1 / Condition Level: Permit
1 / Condition Effective Date: Jun 30, 2026
1 / Status: Applied
1 / Applied By Department: Urban Forestry
2 / Accela Id: 00000REC2602AV9
2 / Permit Number: RES-NEW-26-003664
2 / Permit Status: Inspection Phase
2 / Permit Status Date: Jun 30, 2026
2 / Name: OCC - Final Site Inspection
2 / Condition Level: Permit
2 / Condition Effective Date: Jun 30, 2026
2 / Status: Applied
2 / Applied By Department: City of Charlotte_Construction Site Inspectors
3 / Accela Id: 00000REC2602AV9
3 / Permit Number: RES-NEW-26-003664
3 / Permit Status: Inspection Phase
3 / Permit Status Date: Jun 30, 2026
3 / Name: PMT - Post Construction BMP
3 / Comment: issues with bonding please contact Tom Hodge at 980-314-3203
3 / Condition Level: Address
3 / Condition Effective Date: Jun 30, 2023
3 / Status: Applied
3 / Applied By Department: County Storm Water Land Development
4 / Accela Id: 00000REC2602AV9
4 / Permit Number: RES-NEW-26-003664
4 / Permit Status: Inspection Phase
4 / Permit Status Date: Jun 30, 2026
4 / Name: OCC - Occupancy Final Inspection
4 / Condition Level: Permit
4 / Status: Applied
4 / Applied By Department: Urban Forestry
- Record source
- Mecklenburg Accela