← Back to Charlotte, NC homes for sale

1908 Kilborne Drive, Charlotte, NC

Charlotte, NC 28205

$625,000
Est. $3,998/mo
3Beds
2Baths
1,643Sq Ft
0.22Acre Lot
1955Built
DishwasherElectric CooktopElectric OvenExhaust FanExhaust Hood

The space you want, the updates you need, and a location you’ll love! This beautifully renovated 3-bedroom, 2-bath ranch in desirable Country Club Heights offers 1,728 square feet of comfortable living space. Highlights include an updated kitchen, an expansive primary bedroom…

Show more

The space you want, the updates you need, and a location you’ll love! This beautifully renovated 3-bedroom, 2-bath ranch in desirable Country Club Heights offers 1,728 square feet of comfortable living space. Highlights include an updated kitchen, an expansive primary bedroom with room for a sitting area, and inviting spaces for everyday living and entertaining. Enjoy standout curb appeal, mature trees, and a fenced backyard perfect for pets, play, or gatherings. All just minutes from NoDa, Plaza Midwood, and some of Charlotte’s favorite restaurants, breweries, and neighborhood destinations!

Schedule Showing

Property Highlights

  • Driveway

Schools

    Sales History

    Nov 5, 2026Currently listed$625,000
    $380/sqft

    Similar Homes

    All data is deemed reliable but not guaranteed. Canopy MLS via IDX Broker. Information is provided by third parties and is subject to change.

    Listing courtesy of the listing brokerage via Canopy MLS.

    Last updated Nov 5, 2026. Listing ID 4438896.

    Information herein deemed reliable but not guaranteed. Listings are provided courtesy of the Canopy MLS, Inc. via IDX Broker and may not reflect the most current status of properties. Helen Harp Realty does not represent every listing shown. Consumers should independently verify any information before relying on it.

    Presented by Helen Harp Realty / Keller Williams Ballantyne Area

    Find your next home

    Search homes on the map

    Open full IDX map

    Explore properties and draw your search area with IDX Broker.

    Listings provided by Canopy MLS via IDX Broker. Availability and prices may change.

    Property value & market history

    Built from Canopy MLS closed sales and leases and Mecklenburg County public records. Evidence compiled Nov 21, 2026.

    Estimated market-value range

    Range: $539,000 to $750,000

    Median of 3 comparable closed sales: $645,000

    Comparable-sales range as of Nov 21, 2026 · method pv-1.0.0 · not an appraisal

    Current asking price $625,000 is the seller's list price. It is not a sale price and is not used in the range.

    Limited evidence: only 3 comparable sales.

    How this range is built
    • Comparable sales: Canopy MLS closed sales of the same property sub-type in ZIP 28205, within 1 mile and 6 months by default, living area within ±20% and year built within ±20 years of the subject; sales in the same subdivision are used when at least 3 qualify; nearest 8 kept.
    • Closed price and close date are read from each sale's MLS record. Asking prices, tax assessments and deed transfers are never used as sale prices.
    • At least 3 qualified sales are required before any range is shown (Home Value Lab rules, model hvl-selected-comp-1.0.0).
    • This is a comparable-sales range, not an appraisal, broker price opinion or automated valuation model.
    • Limited evidence: only 3 comparable sales.
    • Comparable sales come from the subject's ZIP code (28205); sales across a ZIP boundary are not searched.
    • The range is the lowest to highest of the selected comparable closed prices, and the midpoint is their median. No adjustments are made for condition, upgrades, lot, view or concessions.

    Comparable closed sales 3

    Same subdivision (Country Club Heights), closed within 6 months and 1 mi, nearest first.

    AddressClosedClosed priceSq ft$/sq ftBuiltBeds / bathsDistance
    1914 Windham Place, CharlotteJul 14, 2026$645,0001,751$36819593 / 20.07 mi
    1924 Bentley Place, CharlotteJul 13, 2026$750,0001,533$48919643 / 30.35 mi
    2508 Hilliard Drive, CharlotteJul 23, 2026$539,0001,502$35919553 / 20.57 mi

    Closed price and date from each sale's Canopy MLS record via IDX Broker. Subject: 1,643 sq ft, built 1955.

    Sale & listing-price history

    Sale and asking-price history7 priced events from 2012 to 2026. The same events are listed in the table below the chart.$0K$100K$200K$300K$400K$500K$600K$700K20122014201620182020202220242026County-recorded deed, county marks it not qualified: $40,000, Aug 31, 2012County-recorded deed, county marks it a qualified sale: $110,000, Jun 28, 2013County-recorded deed, county marks it a qualified sale: $225,000, Sep 1, 2020County-recorded deed, county marks it not qualified: $305,000, Jan 5, 2022MLS closed sale: $570,000, Aug 7, 2024County-recorded deed, county marks it a qualified sale: $570,000, Aug 9, 2024MLS asking price (not a sale): $625,000, Nov 5, 2026
    DateEventAmountReference
    Nov 5, 2026Current MLS asking price (observed)$625,000MLS #4438896
    Jul 31, 2026Recorded transfer, nominal or no considerationNo consideration recordedDeed book-page 40614-048 (QC)
    Aug 9, 2024County-recorded deed (county marks qualified sale)$570,000Deed book-page 38994-99 (WD)
    Aug 7, 2024MLS closed sale$570,000MLS #4141248
    Jan 5, 2022County-recorded deed (county marks not qualified)$305,000Deed book-page 36942-477 (WD)
    Sep 1, 2020County-recorded deed (county marks qualified sale)$225,000Deed book-page 35003-539 (WD)
    Jun 28, 2013County-recorded deed (county marks qualified sale)$110,000Deed book-page 28483-689 (WD)
    Aug 31, 2012County-recorded deed (county marks not qualified)$40,000Deed book-page 27625-680 (WD)
    May 14, 1975Recorded transfer, nominal or no considerationNo consideration recordedDeed book-page 03756-442 (DS)

    Only MLS closed sales are verified sale prices. County deed amounts are recorded consideration; the county's own qualified-sale flag is shown as recorded, and nominal transfers are not plotted. County records: Mecklenburg POLARIS parcel 09314138, retrieved Nov 21, 2026. Earlier MLS listings that did not sell are not available from this source.

    County tax assessment

    The assessed value is set by the county for property tax. It is not a market value and not a sale price.

    Tax yearTotal assessedLandBuildingYard items
    2026$469,200$110,000$359,200$0

    Mecklenburg County GeoPortal assessment table (tb_allparceldata), parcel 09314138.

    Rental range

    $1,280 – $2,500 per month, median $1,650

    From 3 closed MLS leases of the same property type and size band within 1 mi and 6 months. Asking rents are not used.

    Lease comparables
    • 1969 Margate Avenue, Charlotte — $1,650/mo, leased Jun 26, 2026, 0.14 mi
    • 2727 Springway Drive, Charlotte — $2,500/mo, leased Jul 2, 2026, 0.48 mi
    • 2642 Arnold Drive, Charlotte — $1,280/mo, leased Jul 29, 2026, 0.6 mi

    Monthly payment calculator

    Enter your own assumptions. This is arithmetic on your numbers, not a loan offer or a statement that you qualify.

    Pre-filled with the asking price; change it freely.
    Enter a price, down payment, rate and term to see a monthly figure.

    Sold and leased information is provided by Canopy MLS, Inc. via IDX Broker and is deemed reliable but not guaranteed. Public-record data is from Mecklenburg County where shown. This section is not an appraisal, a broker price opinion or an automated valuation, and it is not a lender's determination.

    Free Property Report

    Property records, flood, schools and market for this home

    Free to read and download. No sign-up, no email.

    Download Free Property Report

    Parcel identity verified. Exact Mecklenburg County address-register match on street number, street name and ZIP (one candidate). Parcel ID 09314138.

    Permitted work at a glance

    Partly available

    A brief guide to every returned permit record. Follow each job to its complete description, available inspections and source records.

    Source: Official county permit and inspection records · Retrieved: Nov 26, 2026

    County parcel and lot

    Verified source
    County GIS lot outline, about 152 ft across.
    Parcel ID
    09314138
    County address
    1908 KILBORNE DR CHARLOTTE
    Land use
    Single Family Residential
    Municipality
    Charlotte
    Recorded land area
    0.000 acres
    Mapped parcel area
    9,657 sq ft (GIS)
    Legal description
    L20 B9 M7-459
    Fire district
    City Of Charlotte
    County neighborhood code
    J312
    County building records
    UseYear builtHeated sq ftBedsFull bathsStoriesExterior
    Single-Family19551,908311 StoryFace Brick

    County building records can cover more than one dwelling on a parcel.

    Source: Mecklenburg County POLARIS · Retrieved: Nov 26, 2026

    Taxes, assessments and recorded sales

    Verified source
    Tax municipality
    Charlotte
    Special tax district
    None
    Fire tax district
    City Of Charlotte
    Assessed values by tax year
    Tax yearLandBuildingsYard itemsTotal assessed
    2026$110,000$359,200—$469,200
    Recorded transfers
    RecordedDeed considerationDeed typeCounty-qualified saleBook-page
    Jul 31, 2026None recordedQCNo40614-048
    Aug 9, 2024$570,000WDYes38994-99
    Jan 5, 2022$305,000WDNo36942-477
    Sep 1, 2020$225,000WDYes35003-539
    Jun 28, 2013$110,000WDYes28483-689
    Aug 31, 2012$40,000WDNo27625-680
    May 14, 1975None recordedDSYes03756-442

    Assessed value is the county tax value, not a market value or asking price. Deed consideration is the amount recorded on the deed; it can be zero or a non-market transfer and is not a verified closed-sale price. The annual tax bill is not shown: the county bill search did not answer automatically. Use the tax bill link under Public records.

    Source: Mecklenburg County Assessor (GeoPortal) and POLARIS · Retrieved: Nov 26, 2026

    FEMA flood and environmental layers

    Partly available
    FEMA FIRM panel (effective date)
    3710456400K (02/20/2014)
    FEMA flood zone (parcel)
    Outside
    Community (future-conditions) floodplain
    Outside
    Water-quality buffer
    Outside
    Post-construction stormwater district
    Central Catawba
    Stream watershed district
    BRIAR
    Parcel-overlap results by layer
    LayerFinding
    FEMA effective floodplainNone mapped on this parcel
    Community floodplainNone mapped on this parcel
    FIRM panelMapped: 3710456400K · 2014-02-19 · STUDY1 (9,657 sq ft of parcel)
    Stream / water-quality buffersNone mapped on this parcel
    StreamsNone mapped on this parcel
    WatershedMapped: BRIAR (9,657 sq ft of parcel)
    SoilsMapped: CuB · Cecil-Urban land complex, 2 to 8 percent slopes · B (8,847 sq ft of parcel); CuD · Cecil-Urban land complex, 8 to 15 percent slopes · B (810 sq ft of parcel)
    Wetlands (USFWS NWI)Not available from the source right now
    FEMA preliminary floodplainNone mapped on this parcel
    Impervious surfaceMapped: residential · Building · 1,970; residential · Driveway · 571; residential · Walkway · 221
    TerrainGround elevation about 698 ft (USGS sample, 9/1/2017)

    Mapped results describe the parcel polygon, not the house footprint, and are not a flood-insurance determination or elevation certificate. FEMA flood maps for any address: FEMA Map Service Center link under Public records.

    Source: Mecklenburg County floodplain and environmental GIS (FEMA FIRM data), USFWS, USGS · Information date: 11/26/2026 · Retrieved: Nov 26, 2026

    Permit history - full details

    Partly available

    Job 1

    Electrical permit

    Permit details
    Permit number: E4182444 Project number: 433529 Work category: Electrical permit / One/Two Family Recorded status: Complete
    Original job description and scope
    AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW
    Inspection 1
    Inspection Id: 4182444001 Type: RF - Rough Inspection Date: Jun 6, 2022 Status: Failed Result: Failed Inspector: Hargett, Richard Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalRequestsDetailpublic&PosseObjectId=507282783 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 4, 2022 Scheduled Start Date: Jun 6, 2022 Fee Amount: $0.00 Web Source Of Request: IVR Inspection Task Results 1 / Task Performed: RF - Rough Inspection Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4182444001 Inspection Task Results 2 / Received Date: Jun 4, 2022 Inspection Task Results 2 / Requested Date: Jun 6, 2022 Inspection Task Results 2 / Result Date: Jun 6, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Hargett, Richard Inspection Task Results 2 / Task Performed: RF - Rough Inspection Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: RF Inspection Task Results 3 / Defect Code: 31 Inspection Task Results 3 / Defect Description: Cable subject to damage Inspection Task Results 4 / Task: RF Inspection Task Results 4 / Defect Code: 37 Inspection Task Results 4 / Defect Description: Need stud guards Inspection Task Results 5 / Task: RF Inspection Task Results 5 / Defect Code: 52 Inspection Task Results 5 / Defect Description: General use receptacle spacing Inspection Task Results 6 / Task: RF Inspection Task Results 6 / Defect Code: A8 Inspection Task Results 6 / Defect Description: Need additional/amended permits Inspection Task Results 6 / Defect Note: Work exceeds the scope permitted, or is incorrectly permitted because of the scope of work and needs additional or amended permits as described in inspection notes. Inspection Task Results 7 / Task: RF Inspection Task Results 7 / Defect Code: A9 Inspection Task Results 7 / Defect Description: No specific defect item applies Inspection Task Results 7 / Defect Note: No specific defect item applies from published listing: inspector must enter appropriate notes to identify item.
    Inspection 2
    Inspection Id: 4182444003 Type: FI - Final Inspection Date: Aug 17, 2022 Status: Cancelled Result: Cancelled Inspector: Hathcock, Josh Comments: FI - Final Inspection: Cancelled per contractor, David Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalRequestsDetailpublic&PosseObjectId=528266253 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Aug 14, 2022 Scheduled Start Date: Aug 17, 2022 Fee Amount: $0.00 Web Source Of Request: IVR Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: Not Done Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4182444003 Inspection Task Results 2 / Received Date: Aug 14, 2022 Inspection Task Results 2 / Requested Date: Aug 17, 2022 Inspection Task Results 2 / Result Date: Aug 17, 2022 Inspection Task Results 2 / Overall Result: Cancelled Inspection Task Results 2 / Inspector: Hathcock, Josh Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: Not Done Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 3
    Inspection Id: 4182444002 Type: RF - Rough Inspection Date: Jun 29, 2022 Status: Passed Result: Passed Inspector: Hathcock, Josh Comments: RF - Rough Inspection: Whole house remodel, relocate service Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalRequestsDetailpublic&PosseObjectId=514476666 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 28, 2022 Scheduled Start Date: Jun 29, 2022 Fee Amount: $0.00 Web Source Of Request: IVR Inspection Task Results 1 / Task Performed: RF - Rough Inspection Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4182444002 Inspection Task Results 2 / Received Date: Jun 28, 2022 Inspection Task Results 2 / Requested Date: Jun 29, 2022 Inspection Task Results 2 / Result Date: Jun 29, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Hathcock, Josh Inspection Task Results 2 / Task Performed: RF - Rough Inspection Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 4
    Inspection Id: 4182444005 Type: FI - Final Inspection Date: Sep 13, 2022 Status: Failed Result: Failed Inspector: Hathcock, Josh Comments: FI - Final Inspection: 1) panel cover screws are stripped out 2) bond screw is loose from panel skin 3) separate neturals and grounds at sub panel 4) line/load reversed at ac and wh disconnects 5) need GFCI protection on laundry 110 outlets 6) need box extension on devices at kitchen in tile backsplash 8) cooktop junction box is not accessible 9) need manufacturer installation instructions for all appliances Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalRequestsDetailpublic&PosseObjectId=537242543 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Sep 13, 2022 Scheduled Start Date: Sep 13, 2022 Fee Amount: $0.00 Web Source Of Request: IVR Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4182444005 Inspection Task Results 2 / Received Date: Sep 13, 2022 Inspection Task Results 2 / Requested Date: Sep 13, 2022 Inspection Task Results 2 / Result Date: Sep 13, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Hathcock, Josh Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: FI Inspection Task Results 3 / Defect Code: 08 Inspection Task Results 3 / Defect Description: Service Inspection Task Results 4 / Task: FI Inspection Task Results 4 / Defect Code: 10 Inspection Task Results 4 / Defect Description: Bonding Inspection Task Results 5 / Task: FI Inspection Task Results 5 / Defect Code: 41 Inspection Task Results 5 / Defect Description: Improper joints or terminations Inspection Task Results 6 / Task: FI Inspection Task Results 6 / Defect Code: 55 Inspection Task Results 6 / Defect Description: GFCI defect general Inspection Task Results 7 / Task: FI Inspection Task Results 7 / Defect Code: 62 Inspection Task Results 7 / Defect Description: Need extension rings on devices or boxes Inspection Task Results 8 / Task: FI Inspection Task Results 8 / Defect Code: 81 Inspection Task Results 8 / Defect Description: Line and load reversed in disconnect Inspection Task Results 9 / Task: FI Inspection Task Results 9 / Defect Code: A9 Inspection Task Results 9 / Defect Description: No specific defect item applies Inspection Task Results 9 / Defect Note: No specific defect item applies from published listing: inspector must enter appropriate notes to identify item.
    Inspection 5
    Inspection Id: 4182444004 Type: FI - Final Inspection Date: Sep 8, 2022 Status: Cancelled Result: Cancelled Inspector: Hathcock, Josh Comments: FI - Final Inspection: Cancelled per contractor, Lyn Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalRequestsDetailpublic&PosseObjectId=535400510 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Sep 6, 2022 Scheduled Start Date: Sep 7, 2022 Fee Amount: $0.00 Web Source Of Request: IVR Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: Not Done Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4182444004 Inspection Task Results 2 / Received Date: Sep 6, 2022 Inspection Task Results 2 / Requested Date: Sep 7, 2022 Inspection Task Results 2 / Result Date: Sep 8, 2022 Inspection Task Results 2 / Overall Result: Cancelled Inspection Task Results 2 / Inspector: Hathcock, Josh Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: Not Done Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 6
    Inspection Id: 4182444006 Type: FI - Final Inspection Date: Sep 19, 2022 Status: Passed Result: Passed Inspector: Hathcock, Josh Comments: FI - Final Inspection: Previous defects corrected Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalRequestsDetailpublic&PosseObjectId=539001301 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Sep 17, 2022 Scheduled Start Date: Sep 19, 2022 Fee Amount: $0.00 Web Source Of Request: IVR Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4182444006 Inspection Task Results 2 / Received Date: Sep 17, 2022 Inspection Task Results 2 / Requested Date: Sep 19, 2022 Inspection Task Results 2 / Result Date: Sep 19, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Hathcock, Josh Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Document 1
    Title: Permit Document Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=490895283
    Document 2
    Title: View Certificate of Compliance Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=539421981
    Document 3
    Title: View Certificate of Occupancy Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=553965688
    Related record 1
    Project Number: 433529 Title: AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=Project&PosseObjectId=473444465 Relationship: County Project
    Additional Permit Details
    Inspection Results: Inspection Results Master Number: B4143365 Permit Document: Permit Document View Certifcate Of Compliance: View Certificate of Compliance Project Address: 1908 KILBORNE DR Parcel Number: 09314138 Tax Jurisdiction: CHARLOTTE Project Phase: Open Job Location: Within setbacks Typeof Building: Addition to existing Bldg Property Use: Residential - One/Two Family USDCCode: 434 - Res Dwelling - CO required (Add, Alteration, Repair) Electrical Construction Cost: $3,800 Total Of All Equipment: $0.00 Equipment Cost At100: $0.00 Cost At20Percent: $0.00 Total Equip Fee: $0.00 Total Electrical Cost: $3,800 Contractor ID: X30961 Permit Fee: $71.89 Fire Damage Surcharge: $0.00 Commercial Surcharge Fee: $0.00 Fee Adjustment: $0.00 Triple Permit Fee Penalty: $0.00 Tech Surcharge: $0.00 Total Fee: $0.00 Entry Date: 04/08/2022 02:39 pm Created By User Name: Wright, Casena Validation Date: 04/08/2022 12:00 am Issued By: Wright, Casena Electrical Utility Company: Duke Energy Total Amps: 200 Numberof Circuits: 5 Circuitsat120Volts: 3 Circuitsover120Volts: 2
    Project Details
    1 / Web Project Address: 1908 KILBORNE DR 1 / Parcel Number: 09314138 1 / Tax Jurisdiction: CHARLOTTE 1 / Project Status: Open 1 / Plan Review Status: Plan Review Status 1 / Building Permits Issued: 1 1 / Building Permits Required: 1 1 / Electrical Permits Issued: 1 1 / Electrical Permits Required: 1 1 / Mechanical Permits Issued: 1 1 / Mechanical Permits Required: 1 1 / Plumbing Permits Issued: 1 1 / Plumbing Permits Required: 1 1 / Zoning Permits Issued: 0 1 / Zoning Use Permits Required: 0 1 / Other Permits Issued: 0 1 / Other Permits Required: 0 1 / Total Issued Permits: 4 1 / Total Required Permits: 4 1 / TCODisplay Date: Not Issued 1 / Certificate Of Occupancy Type: Issued 1 / View Certificate Of Occupancy: View Certificate of Occupancy 1 / Certificate Of Occupancy Issued: Nov 3, 2022 1 / Is Gas Utility Type: Yes 1 / Is Electrical Utility Type: Yes 1 / Utility Date: Nov 3, 2022 1 / RTAPs: RTAP Number Closed RTAP Level Permit Number RTAP for Project Number Base Project Number Inspector Inspector Number Comments
    Record source
    Mecklenburg legacy WebPermit/POSSE

    Job 2

    Building permit — Addition (expand footprint)

    Permit details
    Permit number: B4143365 Project number: 433529 Work category: Building permit / One/Two Family Recorded status: Complete Reported project value: $124,700
    Original job description and scope
    Addition (expand footprint). Room Addition.
    Recorded dates
    Applied: 02/08/2022 11:36 am Issued: 04/08/2022 12:00 am
    Inspection 1
    Inspection Id: 4143365003 Type: FR - Framing Date: Apr 28, 2022 Status: Cancelled Result: Cancelled Inspector: Gomez, Jaime Comments: FR - Framing: No required inspection Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=496241248 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Apr 27, 2022 Scheduled Start Date: Apr 28, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FR - Framing Inspection Task Results 1 / Result: Not Done Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4143365003 Inspection Task Results 2 / Received Date: Apr 27, 2022 Inspection Task Results 2 / Requested Date: Apr 28, 2022 Inspection Task Results 2 / Result Date: Apr 28, 2022 Inspection Task Results 2 / Overall Result: Cancelled Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FR - Framing Inspection Task Results 2 / Result: Not Done Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 2
    Inspection Id: 4143365002 Type: FD - Foundation Date: Apr 22, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=493895166 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Apr 20, 2022 Scheduled Start Date: Apr 21, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FD - Foundation Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4143365002 Inspection Task Results 2 / Received Date: Apr 20, 2022 Inspection Task Results 2 / Requested Date: Apr 21, 2022 Inspection Task Results 2 / Result Date: Apr 22, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FD - Foundation Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 3
    Inspection Id: 4143365004 Type: FR - Framing Date: Jun 2, 2022 Status: Failed Result: Failed Inspector: Gomez, Jaime Comments: FR - Framing: Job not ready in progress now to get it ready Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=504574650 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: May 25, 2022 Scheduled Start Date: May 26, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FR - Framing Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4143365004 Inspection Task Results 2 / Received Date: May 25, 2022 Inspection Task Results 2 / Requested Date: May 26, 2022 Inspection Task Results 2 / Result Date: Jun 2, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FR - Framing Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: FR Inspection Task Results 3 / Defect Code: A4 Inspection Task Results 3 / Defect Description: Inspection Not Started - Job Not Ready Inspection Task Results 3 / Defect Note: Inspection cannot start - task being inspected is not finished upon inspector arrival. Recommending contractor review site and reschedule when ready.
    Inspection 4
    Inspection Id: 4143365001 Type: FT - Footing Date: Apr 13, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=491615493 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Apr 12, 2022 Scheduled Start Date: Apr 13, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FT - Footing Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4143365001 Inspection Task Results 2 / Received Date: Apr 12, 2022 Inspection Task Results 2 / Requested Date: Apr 13, 2022 Inspection Task Results 2 / Result Date: Apr 13, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FT - Footing Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 5
    Inspection Id: 4143365005 Type: FT - Footing Date: Jun 2, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Comments: FT - Footing: Deck Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=506409639 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 1, 2022 Scheduled Start Date: Jun 2, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FT - Footing Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4143365005 Inspection Task Results 2 / Received Date: Jun 1, 2022 Inspection Task Results 2 / Requested Date: Jun 2, 2022 Inspection Task Results 2 / Result Date: Jun 2, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FT - Footing Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 6
    Inspection Id: 4143365006 Type: FR - Framing; SH - Sheathing Date: Jun 6, 2022 Status: Inaccessible Result: Inaccessible Inspector: Howie, Dustin Comments: FR - Framing: Key box on door. No code provided. Door locked. SH - Sheathing: Key box on door. No code provided. Door locked. Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=507280601 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 4, 2022 Scheduled Start Date: Jun 6, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FR - Framing Inspection Task Results 1 / Result: 03 - Inaccessible Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Task Performed: SH - Sheathing Inspection Task Results 2 / Result: 03 - Inaccessible Inspection Task Results 2 / Count As Failure: 0 Inspection Task Results 3 / Confirmation Number: 4143365006 Inspection Task Results 3 / Received Date: Jun 4, 2022 Inspection Task Results 3 / Requested Date: Jun 6, 2022 Inspection Task Results 3 / Result Date: Jun 6, 2022 Inspection Task Results 3 / Overall Result: Inaccessible Inspection Task Results 3 / Inspector: Howie, Dustin Inspection Task Results 3 / Task Performed: FR - Framing Inspection Task Results 3 / Result: 03 - Inaccessible Inspection Task Results 3 / Defect Results: Task Defect Code Defect Description Defect Note Inspection Task Results 4 / Confirmation Number: 4143365006 Inspection Task Results 4 / Received Date: Jun 4, 2022 Inspection Task Results 4 / Requested Date: Jun 6, 2022 Inspection Task Results 4 / Result Date: Jun 6, 2022 Inspection Task Results 4 / Overall Result: Inaccessible Inspection Task Results 4 / Inspector: Howie, Dustin Inspection Task Results 4 / Task Performed: SH - Sheathing Inspection Task Results 4 / Result: 03 - Inaccessible Inspection Task Results 4 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 7
    Inspection Id: 4143365008 Type: FR - Framing Date: Jun 10, 2022 Status: Failed Result: Failed Inspector: Gomez, Jaime Comments: FR - Framing: Job still not ready Need completed and full county plans Fire stop cable exterior wall by laundry room Missing faces nails at windows and doors headers Blocking seams to wall braces all Strapped new exterior wall to existing at top Regular #2 SYP cannot be in contact with bricks veneer Existing ceiling missing exterior wall to gable support ceiling removed Missing collar ties Shimmed headers by kitchen Missing nailing king to header?s Fire stop missing Fire blocking new addition wall New addition missing ridge support at end New addiction collar ties missing Nailing together double 2 x 8 ridge new addition Need clear requested from electric that need new electric permit. Can be more items after full set of plans provided Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=507747737 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 6, 2022 Scheduled Start Date: Jun 7, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FR - Framing Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4143365008 Inspection Task Results 2 / Received Date: Jun 6, 2022 Inspection Task Results 2 / Requested Date: Jun 7, 2022 Inspection Task Results 2 / Result Date: Jun 10, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FR - Framing Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: FR Inspection Task Results 3 / Defect Code: 108 Inspection Task Results 3 / Defect Description: Wall bracing installation Inspection Task Results 3 / Defect Note: The inspected task was either incomplete, installed incorrectly, missing, or not per plan. Inspection Task Results 4 / Task: FR Inspection Task Results 4 / Defect Code: 111 Inspection Task Results 4 / Defect Description: Firestop incomplete or missing Inspection Task Results 5 / Task: FR Inspection Task Results 5 / Defect Code: 139 Inspection Task Results 5 / Defect Description: Improper nailing Inspection Task Results 6 / Task: FR Inspection Task Results 6 / Defect Code: 144 Inspection Task Results 6 / Defect Description: Collar ties installation Inspection Task Results 6 / Defect Note: The inspected task was either incomplete, installed incorrectly, missing, or not per plan. Inspection Task Results 7 / Task: FR Inspection Task Results 7 / Defect Code: 150 Inspection Task Results 7 / Defect Description: Studs for beam support Inspection Task Results 8 / Task: FR Inspection Task Results 8 / Defect Code: 151 Inspection Task Results 8 / Defect Description: Blocking at wall sheathing Inspection Task Results 9 / Task: FR Inspection Task Results 9 / Defect Code: 182 Inspection Task Results 9 / Defect Description: Draft-stop installation Inspection Task Results 9 / Defect Note: The inspected task was either incomplete, installed incorrectly, missing, or not per plan.
    Inspection 8
    Inspection Id: 4143365007 Type: FT - Footing; SH - Sheathing Date: Jun 7, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=507746662 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 6, 2022 Scheduled Start Date: Jun 7, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FT - Footing Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Task Performed: SH - Sheathing Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Count As Failure: 0 Inspection Task Results 3 / Confirmation Number: 4143365007 Inspection Task Results 3 / Received Date: Jun 6, 2022 Inspection Task Results 3 / Requested Date: Jun 7, 2022 Inspection Task Results 3 / Result Date: Jun 7, 2022 Inspection Task Results 3 / Overall Result: Passed Inspection Task Results 3 / Inspector: Gomez, Jaime Inspection Task Results 3 / Task Performed: FT - Footing Inspection Task Results 3 / Result: 01 - Passed Inspection Task Results 3 / Defect Results: Task Defect Code Defect Description Defect Note Inspection Task Results 4 / Confirmation Number: 4143365007 Inspection Task Results 4 / Received Date: Jun 6, 2022 Inspection Task Results 4 / Requested Date: Jun 7, 2022 Inspection Task Results 4 / Result Date: Jun 7, 2022 Inspection Task Results 4 / Overall Result: Passed Inspection Task Results 4 / Inspector: Gomez, Jaime Inspection Task Results 4 / Task Performed: SH - Sheathing Inspection Task Results 4 / Result: 01 - Passed Inspection Task Results 4 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 9
    Inspection Id: 4143365009 Type: FR - Framing Date: Jun 24, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Comments: FR - Framing: Need pipe boots to see it at insulation Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=511068746 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 16, 2022 Scheduled Start Date: Jun 17, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FR - Framing Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4143365009 Inspection Task Results 2 / Received Date: Jun 16, 2022 Inspection Task Results 2 / Requested Date: Jun 17, 2022 Inspection Task Results 2 / Result Date: Jun 24, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FR - Framing Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 10
    Inspection Id: 4143365012 Type: FI - Final Inspection Date: Oct 26, 2022 Status: Failed Result: Failed Inspector: Gomez, Jaime Comments: FI - Final Inspection: Correction not made still missing R5 insulation at pull down Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=550937293 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Oct 25, 2022 Scheduled Start Date: Oct 26, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4143365012 Inspection Task Results 2 / Received Date: Oct 25, 2022 Inspection Task Results 2 / Requested Date: Oct 26, 2022 Inspection Task Results 2 / Result Date: Oct 26, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: FI Inspection Task Results 3 / Defect Code: 145 Inspection Task Results 3 / Defect Description: Pull down stair installation Inspection Task Results 4 / Task: FI Inspection Task Results 4 / Defect Code: A12 Inspection Task Results 4 / Defect Description: Previous defects not corrected/Unresolved Inspection Task Results 4 / Defect Note: Defect items identified in a previous inspection have not been completed by the contractor and remain unresolved. Recommending contractor review site, resolve issues, and reschedule when ready.
    Inspection 11
    Inspection Id: 4143365013 Type: FI - Final Inspection Date: Nov 3, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=553136614 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Nov 1, 2022 Scheduled Start Date: Nov 2, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4143365013 Inspection Task Results 2 / Received Date: Nov 1, 2022 Inspection Task Results 2 / Requested Date: Nov 2, 2022 Inspection Task Results 2 / Result Date: Nov 3, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 12
    Inspection Id: 4143365010 Type: IN - Insulation Date: Jul 6, 2022 Status: Passed Result: Passed Inspector: Mensinger, Matthew Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=515094632 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 30, 2022 Scheduled Start Date: Jul 1, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: IN - Insulation Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4143365010 Inspection Task Results 2 / Received Date: Jun 30, 2022 Inspection Task Results 2 / Requested Date: Jul 1, 2022 Inspection Task Results 2 / Result Date: Jul 6, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Mensinger, Matthew Inspection Task Results 2 / Task Performed: IN - Insulation Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 13
    Inspection Id: 4143365011 Type: FI - Final Inspection Date: Oct 19, 2022 Status: Failed Result: Failed Inspector: Bryant, Ben Comments: FI - Final Inspection: 1. Insulation in attic missing and not sufficient per code. 2. No attic access insulation. 3. Pull down attic stairs not secured per manufacturer instructions. Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=547806050 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Oct 16, 2022 Scheduled Start Date: Oct 17, 2022 Fee Amount: $0.00 Web Source Of Request: WEB OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4143365011 Inspection Task Results 2 / Received Date: Oct 16, 2022 Inspection Task Results 2 / Requested Date: Oct 17, 2022 Inspection Task Results 2 / Result Date: Oct 19, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Bryant, Ben Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: FI Inspection Task Results 3 / Defect Code: 121 Inspection Task Results 3 / Defect Description: Insulation missing/exposed or fallen Inspection Task Results 4 / Task: FI Inspection Task Results 4 / Defect Code: 134 Inspection Task Results 4 / Defect Description: Attic access
    Contractor 1
    Role: Building Name: AZTEK GENERAL CONTRS INC License: 66157
    Contractor 2
    Role: Electrical Name: ELECTRIC SOLUTIONS INC License: E23020 ,
    Contractor 3
    Role: Mechanical Name: AIROMATIC HEAT & COOLING License: M30021 , Heating Group 3
    Contractor 4
    Role: Plumbing Name: CAROLINA CLEAN DRAINS LLC License: P32565 , Plumbing
    Document 1
    Title: Permit Document Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=490895283
    Document 2
    Title: Certificate of Occupancy* Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=553965688
    Document 3
    Title: View Certificate of Compliance Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=553905878
    Related record 1
    Project Number: 433529 Title: AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=Project&PosseObjectId=473444465 Relationship: County Project
    Related record 2
    Permit Number: E4182444 Project Number: 433529 Title: Electrical permit Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalPermit&PosseObjectId=490894999 Relationship: Linked County Record
    Related record 3
    Permit Number: M4182442 Project Number: 433529 Title: Mechanical permit Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=MechanicalPermit&PosseObjectId=490894987 Relationship: Linked County Record
    Related record 4
    Permit Number: P4182443 Project Number: 433529 Title: Plumbing permit Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=PlumbingPermit&PosseObjectId=490894993 Relationship: Linked County Record
    Additional Permit Details
    Inspection Results: Inspection Results Permit Document: Permit Document Certificate Of Occupancy: Certificate of Occupancy* Plan Review Status: Plan Review Status View Certificate Of Compliance: View Certificate of Compliance Defect Rate Charge On Pg2: *Defect Rate Charge on pg 2. of CO Project Address: 1908 KILBORNE DR Parcel Number: 09314138 Tax Jurisdiction: CHARLOTTE Project Phase: Open Job Location: Within setbacks Front Setback: 30.0 Left Setback: 5.0 Right Setback: 5.0 Rear Setback: 40.0 Property Use: Residential - One/Two Family USDCCode: 434 - Res Dwelling - CO required (Add, Alteration, Repair) Occupancy: R3 * RESIDENTIAL - SINGLE FAMILY Construction Type: 5B * WOOD FRAME/UNPROTECTED Heated Square Feet: 464 Unheated Square Feet: 20 Deck Area: 160 Cnvrt Unhtd To Htd Sq Ft: 175 Renovated Area: 1110 Number Of Stories: 1.0 Number Of Units: 1 Number Of Rooms: 7 Number Of Bedrooms: 3 Number Of Baths: 2.0 Number Of Handicapped Units: 0 Building Contract Cost: $112,000 Sub Permits Contract Cost: $12,700 Total Of All Equipment: $0.00 Equipment Costat100: $0.00 Cost At20Percent: $0.00 Total Equip Fee: $0.00 Building Conrtractor Contr ID: X47542 AZTEK GENERAL CONTRS INC Total Amps: 200 Circuits At120Volts: 3 Number Of Circuits: 5 Circuits Over120Volts: 2 Electrical Service: Existing Electric Utility Company: Duke Energy Heat Pump: Yes Number Of Fixtures: 7 Number Of Plumbing Appliances: 0 Utilities: Existing Public Util Indiv Meter Conn Water: Yes Public Util Indiv Meter Conn Sewer: Yes Permit Fee Type: Construction Permit Fee: $1,055.37 Triple Permit Fee Penalty: $0.00 NESHAPFee: $0.00 Fire Damage Surcharge: $0.00 Fee Adjustment: $0.00 Tech Surcharge: $0.00 Total Fee: $1,120.37 Fast Track Fee: $0.00 Commercial Surcharge Fee: $0.00 Created By User Name: AZTEK GENERAL CONTRS INC Issued By: Wright, Casena
    Project Details
    1 / Web Project Address: 1908 KILBORNE DR 1 / Parcel Number: 09314138 1 / Tax Jurisdiction: CHARLOTTE 1 / Project Status: Open 1 / Plan Review Status: Plan Review Status 1 / Building Permits Issued: 1 1 / Building Permits Required: 1 1 / Electrical Permits Issued: 1 1 / Electrical Permits Required: 1 1 / Mechanical Permits Issued: 1 1 / Mechanical Permits Required: 1 1 / Plumbing Permits Issued: 1 1 / Plumbing Permits Required: 1 1 / Zoning Permits Issued: 0 1 / Zoning Use Permits Required: 0 1 / Other Permits Issued: 0 1 / Other Permits Required: 0 1 / Total Issued Permits: 4 1 / Total Required Permits: 4 1 / TCODisplay Date: Not Issued 1 / Certificate Of Occupancy Type: Issued 1 / View Certificate Of Occupancy: View Certificate of Occupancy 1 / Certificate Of Occupancy Issued: Nov 3, 2022 1 / Is Gas Utility Type: Yes 1 / Is Electrical Utility Type: Yes 1 / Utility Date: Nov 3, 2022 1 / RTAPs: RTAP Number Closed RTAP Level Permit Number RTAP for Project Number Base Project Number Inspector Inspector Number Comments
    Permit Remarks
    1 / Title: Permit Remarks 1 / Text: New addition in master bed and kitchen area. New sq ft being added to heated living area is 760 making it a total of 2213 heated sq ft. 1 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=473444464 2 / Title: General 2 / Text: Residential Plan Review needed 2 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=General&PosseObjectId=473444471 3 / Title: General 3 / Text: All square footages were changed on permit to match the plans. Plans were changed and resubmitted with email request to change same on 3/30/2022 3 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=General&PosseObjectId=488100810 4 / Title: Permit Remarks 4 / Text: All square footages were changed on permit to match the plans. Plans were changed and resubmitted with email request to change same on 3/30/2022 4 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=488101743 5 / Title: Permit Remarks 5 / Text: Deleted 5 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=488100818 6 / Title: Permit Remarks 6 / Text: Project # 433529 Decks, deck stairs, railings, footings etc. not part of plan review at this time and are not reviewed for accuracy. Please see 2018 NCBC:R appendix M for code applications Contractor/Inspector Please verify all details are met from the latest Errata- version version of Fig. R602.10.1 from NCDOI/OSFM https://www.ncosfm.gov/residential/2017-2021-approved-amendments-210914residential-code 6 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=488102509 7 / Title: Permit Remarks 7 / Text: RELOCATE EXISTING SERVICE BOX ADN RE-WIRE ENTIRE HOUSE FROM 2 PRONG WIRING TO 3 PRONG WIRING. 7 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=513275229 8 / Title: General 8 / Text: All square footages were changed on permit to match the plans. Plans were changed and resubmitted with email request to change same on 3/30/2022 8 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=General&PosseObjectId=490894982 9 / Title: General 9 / Text: Residential Plan Review needed 9 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=General&PosseObjectId=490894981 10 / Title: Permit Remarks 10 / Text: HVAC equipment may encroach into set-back area by 50%. 10 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=490895037
    Additional Public Detail Rows
    1 / External File Num: E4182444 1 / Issue Date: Apr 8, 2022 1 / Trade Type: E - Electrical 1 / Status Description: Complete 2 / External File Num: M4182442 2 / Issue Date: Apr 8, 2022 2 / Trade Type: M - Mechanical 2 / Status Description: Mechanical Finaled 3 / External File Num: P4182443 3 / Issue Date: Apr 8, 2022 3 / Trade Type: P - Plumbing 3 / Status Description: Complete 4 / Last Update By User Name: AZTEK GENERAL CONTRS INC 4 / Last Update Date: Feb 8, 2022 5 / Last Update By User Name: Calhoun, Edward 5 / Last Update Date: Mar 30, 2022 6 / Last Update By User Name: Edwards, Masika T 6 / Last Update Date: Jun 24, 2022 7 / Last Update By User Name: Wright, Casena 7 / Last Update Date: Apr 8, 2022
    Imported County Permit
    Permit Number: B4143365 Project Address: 1908 KILBORNE DR Parcel Number: 09314138 Issue Date Iso: Apr 8, 2022 Permit Type: One/Two Family Subtrade: 473444448 Project Number: 433529 Project Name: AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW Construction Cost: $124,700 Usdc Code: 434 - Res Dwelling - CO required (Add, Alteration, Repair) Zoning Code: R-4 Tax Jurisdiction: CHARLOTTE X Coord: 1469308 Y Coord: 543622 Address Normalized: 1908 KILBORNE DR Source Row: 139627 Row Hash: e1ea366ba7dbff6c2c85ff890df1fb50b98fb4aaebf713a01d9c4c8c15ec63a2
    Additional Job Details
    Attached Carport: N Attached Garage: N Basement: N Building Contract Cost: $112,000 Building Contractor Contractor Address: 4624 KIRKGARD TRL CHARLOTTE NC Building Contractor ID: X47542 Building Contractor License Number: 66157 Building Contractor Name: AZTEK GENERAL CONTRS INC Central Air Conditioning: N Circuits At 120 Volts: 3 Circuits Over 120 Volts: 2 Construction Type: 5B * WOOD FRAME/UNPROTECTED Corner Lot: N Deck Area: 160 Description Of Work: 1908 Kilborne Dr Electric Furnace: N Electric Utility Company: DUKE ENERGY Electrical Contract License Number: E23020 , Electrical Contractor (Contractor): ELECTRIC SOLUTIONS INC Electrical Contractor Address: PO BOX 49192 CHARLOTTE, NC 28277 Electrical Contractor ID: X30961 Electrical Service: Existing Front Setback: 30 Gas Pack: N Gas Or Oil Furnace: N Gas Or Oil Steam: N Heat Pump: Y Heated Square Feet: 464 Housing Indicator: N Irregular Lot: N Left Setback: 5 Masonry Fireplace: N Mechanical Contractor (Contractor): AIROMATIC HEAT & COOLING Mechanical Contractor Address: 9338 DOGWOOD RIDGE DR CHARLOTTE, NC 28227 Mechanical Contractor ID: X43380 Mechanical Contractor License Number: M30021 , Heating Group 3 Number Of Appliances (Mechanical): 0 Number Of Appliances (Plumbing): 0 Number Of Baths: 2 Number Of Bedrooms: 3 Number Of Circuits: 5 Number Of Fixtures: 7 Number Of Gas Connections: 0 Number Of Handicapped Units: 0 Number Of Rooms: 7 Number Of Stories: 1 Number Of Units: 1 Occupancy: R3 * RESIDENTIAL - SINGLE FAMILY Plumbing Contractor (Contractor): CAROLINA CLEAN DRAINS LLC Plumbing Contractor Address: 5424 MAPLEWOOD LANE CHARLOTTE, NC 28227 Plumbing Contractor ID: X49124 Plumbing Contractor License Number: P32565 , Plumbing Prefabricated Fireplace: N Private Utility Community Septic: N Private Utility Community Well: N Private Utility Individual Septic: N Private Utility Individual Well: N Project Cost (Subtotal Mechanical): 0 Project Cost (Subtotal Plumbing): 0 Project Cost (Subtotal Electrical): 0 Public Utility Individual Meter/Connection Sewer: Y Public Utility Individual Meter/Connection Water: Y Public Utility Master Meter/Connection Sewer: N Public Utility Master Meter/Connection Water: N Rear Setback: 40 Right Setback: 5 Sprinkler System: N Sub Trades Contract Cost: $12,700 Through Lot: N Total Amps: 200 Total Fee: 1120 Unheated Square Feet: 20 Utilities: Existing
    Coverage
    Supplemental imported export, 2018-01-02 through 2026-09-18. The county export exceeded its volume limit and may omit jobs. Every matching local row is included; no local 200-record cap is applied.
    Mecklenburg Imported Export Original Description
    1908 Kilborne Dr
    Record source
    Mecklenburg legacy WebPermit/POSSE

    Job 3

    Mechanical permit

    Permit details
    Permit number: M4182442 Project number: 433529 Work category: Mechanical permit / One/Two Family Recorded status: Mechanical Finaled
    Original job description and scope
    AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW
    Recorded dates
    Applied: 04/08/2022 02:39 pm Issued: 04/08/2022 12:00 am
    Inspection 1
    Inspection Id: 4182442001 Type: FI - Final Inspection Date: May 26, 2022 Status: Failed Result: Failed Inspector: Hathcock, Josh Comments: FI - Final Inspection: Missing required inspections, no rough inspections noted on permit detail. Will need rough before a final. Removed other inspections to avoid multiple failures. Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=MechanicalRequestsDetailpublic&PosseObjectId=504834632 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: May 25, 2022 Scheduled Start Date: May 26, 2022 Web Source Of Request: WEB OTIDetails2: OTI Details OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4182442001 Inspection Task Results 2 / Received Date: May 25, 2022 Inspection Task Results 2 / Requested Date: May 26, 2022 Inspection Task Results 2 / Result Date: May 26, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Hathcock, Josh Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: FI Inspection Task Results 3 / Defect Code: A7 Inspection Task Results 3 / Defect Description: Missing required inspections Inspection Task Results 3 / Defect Note: Inspection request is not in the correct sequence in the trade series.
    Inspection 2
    Inspection Id: 4182442002 Type: RF - Rough Inspection Date: Jun 1, 2022 Status: Failed Result: Failed Inspector: Hathcock, Josh Comments: RF - Rough Inspection: Need to update permit details. Currently permit is for rear addition only, however there is new work throughout house, rear addition, kitchen, laundry, family?etc?. Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=MechanicalRequestsDetailpublic&PosseObjectId=505248839 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: May 26, 2022 Scheduled Start Date: May 31, 2022 Web Source Of Request: WEB OTIDetails2: OTI Details OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: RF - Rough Inspection Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Confirmation Number: 4182442002 Inspection Task Results 2 / Received Date: May 26, 2022 Inspection Task Results 2 / Requested Date: May 31, 2022 Inspection Task Results 2 / Result Date: Jun 1, 2022 Inspection Task Results 2 / Overall Result: Failed Inspection Task Results 2 / Inspector: Hathcock, Josh Inspection Task Results 2 / Task Performed: RF - Rough Inspection Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 3 / Task: RF Inspection Task Results 3 / Defect Code: A8 Inspection Task Results 3 / Defect Description: Need additional/amended permits Inspection Task Results 3 / Defect Note: Work exceeds the scope permitted, or is incorrectly permitted because of the scope of work and needs additional or amended permits as described in inspection notes.
    Inspection 3
    Inspection Id: 4182442004 Type: FI - Final Inspection; GT - Gas Test (Air Test On Gas Pipe); PS - Pipe Service Date: Sep 6, 2022 Status: Failed Result: Failed Inspector: Hathcock, Josh Comments: FI - Final Inspection: 1) gas test guage is painted, not visible 2) crawl access must be 22x30 with new unit in crawl 3) missing hose clamps on condensate line 4) dryer vent pipe is damaged, needs replaced, also need to seal drywall around pipe 5) need installation instructions for hood, not on site 6) no gas pipe located at range area per previous notes and project scope 7) bath fans are not vented to outside, no vent pipe connected to front bath fan, no vents found at exterior or roof 8) no access to new attic to inspect bath vents, none found at rear exterior or roof GT - Gas Test (Air Test On Gas Pipe): 1) gas test guage is painted, not visible 2) crawl access must be 22x30 with new unit in crawl 3) missing hose clamps on condensate line 4) dryer vent pipe is damaged, needs replaced, also need to seal drywall around pipe 5) need installation instructions for hood, not on site 6) no gas pipe located at range area per previous notes and project scope 7) bath fans are not vented to outside, no vent pipe connected to front bath fan, no vents found at exterior or roof 8) no access to new attic to inspect bath vents, none found at rear exterior or roof PS - Pipe Service: 1) gas test guage is painted, not visible 2) crawl access must be 22x30 with new unit in crawl 3) missing hose clamps on condensate line 4) dryer vent pipe is damaged, needs replaced, also need to seal drywall around pipe 5) need installation instructions for hood, not on site 6) no gas pipe located at range area per previous notes and project scope 7) bath fans are not vented to outside, no vent pipe connected to front bath fan, no vents found at exterior or roof 8) no access to new attic to inspect bath vents, none found at rear exterior or roof Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=MechanicalRequestsDetailpublic&PosseObjectId=534949817 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Sep 5, 2022 Scheduled Start Date: Sep 6, 2022 Web Source Of Request: WEB OTIDetails2: OTI Details OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 02 - Failed Inspection Task Results 1 / Chargeable Failure: Yes Inspection Task Results 1 / Count As Failure: 1 Inspection Task Results 2 / Task Performed: GT - Gas Test (Air Test On Gas Pipe) Inspection Task Results 2 / Result: 02 - Failed Inspection Task Results 2 / Chargeable Failure: Yes Inspection Task Results 2 / Count As Failure: 1 Inspection Task Results 3 / Task Performed: PS - Pipe Service Inspection Task Results 3 / Result: 02 - Failed Inspection Task Results 3 / Chargeable Failure: Yes Inspection Task Results 3 / Count As Failure: 1 Inspection Task Results 4 / Confirmation Number: 4182442004 Inspection Task Results 4 / Received Date: Sep 5, 2022 Inspection Task Results 4 / Requested Date: Sep 6, 2022 Inspection Task Results 4 / Result Date: Sep 6, 2022 Inspection Task Results 4 / Overall Result: Failed Inspection Task Results 4 / Inspector: Hathcock, Josh Inspection Task Results 4 / Task Performed: FI - Final Inspection Inspection Task Results 4 / Result: 02 - Failed Inspection Task Results 5 / Task: FI Inspection Task Results 5 / Defect Code: D09 Inspection Task Results 5 / Defect Description: Duct for bathroom exhaust missing or incorrect Inspection Task Results 6 / Task: FI Inspection Task Results 6 / Defect Code: D11 Inspection Task Results 6 / Defect Description: Dryer vent missing or incorrect Inspection Task Results 7 / Task: FI Inspection Task Results 7 / Defect Code: E08 Inspection Task Results 7 / Defect Description: Equipment installation instructions not available Inspection Task Results 8 / Task: FI Inspection Task Results 8 / Defect Code: G03 Inspection Task Results 8 / Defect Description: Gas test not to code or bad gauge Inspection Task Results 9 / Task: FI Inspection Task Results 9 / Defect Code: G04 Inspection Task Results 9 / Defect Description: Gas pipe damaged or improperly installed Inspection Task Results 10 / Task: FI Inspection Task Results 10 / Defect Code: P01 Inspection Task Results 10 / Defect Description: Primary or secondary drain missing or incorrect Inspection Task Results 11 / Confirmation Number: 4182442004 Inspection Task Results 11 / Received Date: Sep 5, 2022 Inspection Task Results 11 / Requested Date: Sep 6, 2022 Inspection Task Results 11 / Result Date: Sep 6, 2022 Inspection Task Results 11 / Overall Result: Failed Inspection Task Results 11 / Inspector: Hathcock, Josh Inspection Task Results 11 / Task Performed: GT - Gas Test (Air Test On Gas Pipe) Inspection Task Results 11 / Result: 02 - Failed Inspection Task Results 12 / Task: GT Inspection Task Results 12 / Defect Code: G03 Inspection Task Results 12 / Defect Description: Gas test not to code or bad gauge Inspection Task Results 13 / Confirmation Number: 4182442004 Inspection Task Results 13 / Received Date: Sep 5, 2022 Inspection Task Results 13 / Requested Date: Sep 6, 2022 Inspection Task Results 13 / Result Date: Sep 6, 2022 Inspection Task Results 13 / Overall Result: Failed Inspection Task Results 13 / Inspector: Hathcock, Josh Inspection Task Results 13 / Task Performed: PS - Pipe Service Inspection Task Results 13 / Result: 02 - Failed Inspection Task Results 14 / Task: PS Inspection Task Results 14 / Defect Code: G01 Inspection Task Results 14 / Defect Description: Gas pipe not complete
    Inspection 4
    Inspection Id: 4182442005 Type: FI - Final Inspection; GT - Gas Test (Air Test On Gas Pipe); PS - Pipe Service Date: Sep 13, 2022 Status: Passed Result: Passed Inspector: Hathcock, Josh Comments: FI - Final Inspection: Waf only Gas to range has been removed from manifold and capped GT - Gas Test (Air Test On Gas Pipe): Waf only Gas to range has been removed from manifold and capped PS - Pipe Service: Waf only Gas to range has been removed from manifold and capped Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=MechanicalRequestsDetailpublic&PosseObjectId=536750929 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Sep 10, 2022 Scheduled Start Date: Sep 13, 2022 Web Source Of Request: WEB OTIDetails2: OTI Details OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Task Performed: GT - Gas Test (Air Test On Gas Pipe) Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Count As Failure: 0 Inspection Task Results 3 / Task Performed: PS - Pipe Service Inspection Task Results 3 / Result: 01 - Passed Inspection Task Results 3 / Count As Failure: 0 Inspection Task Results 4 / Confirmation Number: 4182442005 Inspection Task Results 4 / Received Date: Sep 10, 2022 Inspection Task Results 4 / Requested Date: Sep 13, 2022 Inspection Task Results 4 / Result Date: Sep 13, 2022 Inspection Task Results 4 / Overall Result: Passed Inspection Task Results 4 / Inspector: Hathcock, Josh Inspection Task Results 4 / Task Performed: FI - Final Inspection Inspection Task Results 4 / Result: 01 - Passed Inspection Task Results 4 / Defect Results: Task Defect Code Defect Description Defect Note Inspection Task Results 5 / Confirmation Number: 4182442005 Inspection Task Results 5 / Received Date: Sep 10, 2022 Inspection Task Results 5 / Requested Date: Sep 13, 2022 Inspection Task Results 5 / Result Date: Sep 13, 2022 Inspection Task Results 5 / Overall Result: Passed Inspection Task Results 5 / Inspector: Hathcock, Josh Inspection Task Results 5 / Task Performed: GT - Gas Test (Air Test On Gas Pipe) Inspection Task Results 5 / Result: 01 - Passed Inspection Task Results 5 / Defect Results: Task Defect Code Defect Description Defect Note Inspection Task Results 6 / Confirmation Number: 4182442005 Inspection Task Results 6 / Received Date: Sep 10, 2022 Inspection Task Results 6 / Requested Date: Sep 13, 2022 Inspection Task Results 6 / Result Date: Sep 13, 2022 Inspection Task Results 6 / Overall Result: Passed Inspection Task Results 6 / Inspector: Hathcock, Josh Inspection Task Results 6 / Task Performed: PS - Pipe Service Inspection Task Results 6 / Result: 01 - Passed Inspection Task Results 6 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 5
    Inspection Id: 4182442003 Type: GT - Gas Test (Air Test On Gas Pipe); PS - Pipe Service; RF - Rough Inspection Date: Jun 6, 2022 Status: Passed Result: Passed Inspector: Hargett, Richard Comments: GT - Gas Test (Air Test On Gas Pipe): Hvac 1 Waf in crawl space. 1 line for gas range.total house renovation and addition to multiple areas. PS - Pipe Service: Hvac 1 Waf in crawl space. 1 line for gas range.total house renovation and addition to multiple areas. RF - Rough Inspection: Hvac 1 Waf in crawl space. 1 line for gas range.total house renovation and addition to multiple areas. Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=MechanicalRequestsDetailpublic&PosseObjectId=506663784 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 2, 2022 Scheduled Start Date: Jun 3, 2022 Web Source Of Request: Mecklenburg Staff OTIDetails2: OTI Details OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: GT - Gas Test (Air Test On Gas Pipe) Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Task Performed: PS - Pipe Service Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Count As Failure: 0 Inspection Task Results 3 / Task Performed: RF - Rough Inspection Inspection Task Results 3 / Result: 01 - Passed Inspection Task Results 3 / Count As Failure: 0 Inspection Task Results 4 / Confirmation Number: 4182442003 Inspection Task Results 4 / Received Date: Jun 2, 2022 Inspection Task Results 4 / Requested Date: Jun 3, 2022 Inspection Task Results 4 / Result Date: Jun 6, 2022 Inspection Task Results 4 / Overall Result: Passed Inspection Task Results 4 / Inspector: Hargett, Richard Inspection Task Results 4 / Task Performed: GT - Gas Test (Air Test On Gas Pipe) Inspection Task Results 4 / Result: 01 - Passed Inspection Task Results 4 / Defect Results: Task Defect Code Defect Description Defect Note Inspection Task Results 5 / Confirmation Number: 4182442003 Inspection Task Results 5 / Received Date: Jun 2, 2022 Inspection Task Results 5 / Requested Date: Jun 3, 2022 Inspection Task Results 5 / Result Date: Jun 6, 2022 Inspection Task Results 5 / Overall Result: Passed Inspection Task Results 5 / Inspector: Hargett, Richard Inspection Task Results 5 / Task Performed: PS - Pipe Service Inspection Task Results 5 / Result: 01 - Passed Inspection Task Results 5 / Defect Results: Task Defect Code Defect Description Defect Note Inspection Task Results 6 / Confirmation Number: 4182442003 Inspection Task Results 6 / Received Date: Jun 2, 2022 Inspection Task Results 6 / Requested Date: Jun 3, 2022 Inspection Task Results 6 / Result Date: Jun 6, 2022 Inspection Task Results 6 / Overall Result: Passed Inspection Task Results 6 / Inspector: Hargett, Richard Inspection Task Results 6 / Task Performed: RF - Rough Inspection Inspection Task Results 6 / Result: 01 - Passed Inspection Task Results 6 / Defect Results: Task Defect Code Defect Description Defect Note
    Contractor 1
    Role: Mechanical Name: AIROMATIC HEAT & COOLING
    Document 1
    Title: Permit Document Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=490895283
    Document 2
    Title: View Certificate of Occupancy Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=553965688
    Related record 1
    Project Number: 433529 Title: AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=Project&PosseObjectId=473444465 Relationship: County Project
    Additional Permit Details
    Inspection Results: Inspection Results Master Number: B4143365 Permit Document: Permit Document Project Address: 1908 KILBORNE DR Parcel Number: 09314138 Tax Jurisdiction: CHARLOTTE Project Phase: Open Job Location: Within setbacks Type Of Building: Addition to existing Bldg Property Use: Residential - One/Two Family Mechanical Construction Cost: $4,200 USDCCode: 434 - Res Dwelling - CO required (Add, Alteration, Repair) Contractor ID: X43380 Licence Number: 30021 Permit Fee: $84.08 Fire Damage Surcharge: $0.00 Commercial Surcharge Fee: $0.00 Fee Adjustment: $0.00 Triple Permit Fee Penalty: $0.00 Tech Surcharge: $0.00 Total Fee: $0.00 Created By User Name: Wright, Casena Issued By: Wright, Casena Utility Company: PIEDMONT NATURAL GAS Floor Furnace Quantity: 1 Exhaust Fan Quantity: 2 Exhaust Hood Quantity: 1 Ductwork HVACOnly Qty: 1 Fan Coil Unit Quantity: 1 Range Quantity: 1 Other Gas Piping Description1: Dryer Duct Other Gas Piping Qty1: 1 Other Gas Piping Description2: Condenser Unit Other Gas Piping Qty2: 1 Heat Pump: Yes
    Project Details
    1 / Web Project Address: 1908 KILBORNE DR 1 / Parcel Number: 09314138 1 / Tax Jurisdiction: CHARLOTTE 1 / Project Status: Open 1 / Plan Review Status: Plan Review Status 1 / Building Permits Issued: 1 1 / Building Permits Required: 1 1 / Electrical Permits Issued: 1 1 / Electrical Permits Required: 1 1 / Mechanical Permits Issued: 1 1 / Mechanical Permits Required: 1 1 / Plumbing Permits Issued: 1 1 / Plumbing Permits Required: 1 1 / Zoning Permits Issued: 0 1 / Zoning Use Permits Required: 0 1 / Other Permits Issued: 0 1 / Other Permits Required: 0 1 / Total Issued Permits: 4 1 / Total Required Permits: 4 1 / TCODisplay Date: Not Issued 1 / Certificate Of Occupancy Type: Issued 1 / View Certificate Of Occupancy: View Certificate of Occupancy 1 / Certificate Of Occupancy Issued: Nov 3, 2022 1 / Is Gas Utility Type: Yes 1 / Is Electrical Utility Type: Yes 1 / Utility Date: Nov 3, 2022 1 / RTAPs: RTAP Number Closed RTAP Level Permit Number RTAP for Project Number Base Project Number Inspector Inspector Number Comments
    Permit Remarks
    1 / Title: Permit Remarks 1 / Text: HVAC equipment may encroach into set-back area by 50%. 1 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=490895233
    Additional Public Detail Rows
    1 / Last Update By User Name: Wright, Casena 1 / Last Update Date: Apr 8, 2022
    Record source
    Mecklenburg legacy WebPermit/POSSE

    Job 4

    Plumbing permit

    Permit details
    Permit number: P4182443 Project number: 433529 Work category: Plumbing permit / One/Two Family Recorded status: Complete
    Original job description and scope
    AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW
    Recorded dates
    Applied: 04/08/2022 02:39 pm Issued: 04/08/2022 12:00 am
    Inspection 1
    Inspection Id: 4182443003 Type: FI - Final Inspection Date: Sep 9, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=PlumbingRequestsDetailpublicVi&PosseObjectId=536352099 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Sep 9, 2022 Scheduled Start Date: Sep 9, 2022 Fee Amount: 0 Web Source Of Request: WEB Requested Tasks New: FI OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: FI - Final Inspection Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4182443003 Inspection Task Results 2 / Received Date: Sep 9, 2022 Inspection Task Results 2 / Requested Date: Sep 9, 2022 Inspection Task Results 2 / Result Date: Sep 9, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Gomez, Jaime Inspection Task Results 2 / Task Performed: FI - Final Inspection Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 2
    Inspection Id: 4182443001 Type: RF - Rough Inspection; WD - Water Distribution Date: May 18, 2022 Status: Passed Result: Passed Inspector: Gomez, Jaime Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=PlumbingRequestsDetailpublicVi&PosseObjectId=502245777 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: May 17, 2022 Scheduled Start Date: May 18, 2022 Fee Amount: 0 Web Source Of Request: WEB Requested Tasks New: RF, WD OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: RF - Rough Inspection Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Task Performed: WD - Water Distribution Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Count As Failure: 0 Inspection Task Results 3 / Confirmation Number: 4182443001 Inspection Task Results 3 / Received Date: May 17, 2022 Inspection Task Results 3 / Requested Date: May 18, 2022 Inspection Task Results 3 / Result Date: May 18, 2022 Inspection Task Results 3 / Overall Result: Passed Inspection Task Results 3 / Inspector: Gomez, Jaime Inspection Task Results 3 / Task Performed: RF - Rough Inspection Inspection Task Results 3 / Result: 01 - Passed Inspection Task Results 3 / Defect Results: Task Defect Code Defect Description Defect Note Inspection Task Results 4 / Confirmation Number: 4182443001 Inspection Task Results 4 / Received Date: May 17, 2022 Inspection Task Results 4 / Requested Date: May 18, 2022 Inspection Task Results 4 / Result Date: May 18, 2022 Inspection Task Results 4 / Overall Result: Passed Inspection Task Results 4 / Inspector: Gomez, Jaime Inspection Task Results 4 / Task Performed: WD - Water Distribution Inspection Task Results 4 / Result: 01 - Passed Inspection Task Results 4 / Defect Results: Task Defect Code Defect Description Defect Note
    Inspection 3
    Inspection Id: 4182443002 Type: RF - Rough Inspection Date: Jun 28, 2022 Status: Passed Result: Passed Inspector: Tompkins, Matthew Comments: RF - Rough Inspection: One shower pan Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=PlumbingRequestsDetailpublicVi&PosseObjectId=512913050 Formatted Address: 1908 KILBORNE DR CHARLOTTE Tax Jurisdiction: CHARLOTTE Received Date: Jun 23, 2022 Scheduled Start Date: Jun 24, 2022 Fee Amount: 0 Web Source Of Request: WEB Requested Tasks New: RF OTIExtension Fee: $0.00 Inspection Task Results 1 / Task Performed: RF - Rough Inspection Inspection Task Results 1 / Result: 01 - Passed Inspection Task Results 1 / Count As Failure: 0 Inspection Task Results 2 / Confirmation Number: 4182443002 Inspection Task Results 2 / Received Date: Jun 23, 2022 Inspection Task Results 2 / Requested Date: Jun 24, 2022 Inspection Task Results 2 / Result Date: Jun 28, 2022 Inspection Task Results 2 / Overall Result: Passed Inspection Task Results 2 / Inspector: Tompkins, Matthew Inspection Task Results 2 / Task Performed: RF - Rough Inspection Inspection Task Results 2 / Result: 01 - Passed Inspection Task Results 2 / Defect Results: Task Defect Code Defect Description Defect Note
    Contractor 1
    Role: Plumbing Name: CAROLINA CLEAN DRAINS LLC
    Document 1
    Title: Permit Document Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=490895283
    Document 2
    Title: View Certificate of Occupancy Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=553965688
    Related record 1
    Project Number: 433529 Title: AZTEK GENERAL CONTRS / Room Addition (expand) / PLN REVIEW Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=Project&PosseObjectId=473444465 Relationship: County Project
    Additional Permit Details
    Inspection Results: Inspection Results Master Number: B4143365 Permit Document: Permit Document Project Address: 1908 KILBORNE DR Parcel Number: 09314138 Tax Jurisdiction: CHARLOTTE Project Phase: Open Job Location: Within setbacks Type Of Building: Addition to existing Bldg Property Use: Residential - One/Two Family Plumbing Construction Cost: $4,700 USDCCode: 434 - Res Dwelling - CO required (Add, Alteration, Repair) Contractor ID: X49124 Licence Number: 32565 Permit Fee: $84.08 Fire Damage Surcharge: $0.00 Commercial Surcharge Fee: $0.00 Fee Adjustment: $0.00 Triple Permit Fee Penalty: $0.00 Tech Surcharge: $0.00 Total Fee: $0.00 Created By User Name: Wright, Casena Issued By: Wright, Casena Public Util Indiv Meter Conn Water: Yes Public Util Indiv Meter Conn Sewer: Yes Numberof Fixtures: 7 Numberof Plumbing Appliances: 0
    Project Details
    1 / Web Project Address: 1908 KILBORNE DR 1 / Parcel Number: 09314138 1 / Tax Jurisdiction: CHARLOTTE 1 / Project Status: Open 1 / Plan Review Status: Plan Review Status 1 / Building Permits Issued: 1 1 / Building Permits Required: 1 1 / Electrical Permits Issued: 1 1 / Electrical Permits Required: 1 1 / Mechanical Permits Issued: 1 1 / Mechanical Permits Required: 1 1 / Plumbing Permits Issued: 1 1 / Plumbing Permits Required: 1 1 / Zoning Permits Issued: 0 1 / Zoning Use Permits Required: 0 1 / Other Permits Issued: 0 1 / Other Permits Required: 0 1 / Total Issued Permits: 4 1 / Total Required Permits: 4 1 / TCODisplay Date: Not Issued 1 / Certificate Of Occupancy Type: Issued 1 / View Certificate Of Occupancy: View Certificate of Occupancy 1 / Certificate Of Occupancy Issued: Nov 3, 2022 1 / Is Gas Utility Type: Yes 1 / Is Electrical Utility Type: Yes 1 / Utility Date: Nov 3, 2022 1 / RTAPs: RTAP Number Closed RTAP Level Permit Number RTAP for Project Number Base Project Number Inspector Inspector Number Comments
    Record source
    Mecklenburg legacy WebPermit/POSSE

    Permit sources and search coverage

    Mecklenburg Accela current permits and inspections · Status: unavailable · Records: 0 · Match: Verified county parcel 09314138 · Checked: Nov 26, 2026 · Coverage: All matched records from the county's public Accela All Permits layer, plus the full publicly returned detail and inspection history for each permit. The county archive determines historical coverage; attachment files are included only when exposed by the public record. · Source: https://gis.mecklenburgcountync.gov/meck-accela

    Source issue 1: The county did not return an object-ID list.

    Mecklenburg legacy WebPermit/POSSE · Status: ready · Records: 4 · Match: Exact verified county parcel 09314138; every returned address and linked public job is followed. · Checked: Nov 26, 2026 · Coverage: Public legacy parcel search, all returned address variants and linked project, permit, trade, inspection, note and document pages. This public search does not establish lifetime archive completeness. · Source: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=SearchByAddress

    Mecklenburg imported permit export (supplemental archive) · Status: partial · Records: 1 · Match: Verified county parcel 09314138 · Checked: Nov 26, 2026 · Coverage: Supplemental imported export, 2018-01-02 through 2026-09-18. The county export exceeded its volume limit and may omit jobs. Every matching local row is included; no local 200-record cap is applied. · Source: https://meck-ent-power-bi-reports-public-web.azurewebsites.net/Viewer?groupId=2ca2c01c-5658-4ee2-8a4f-5bdda8be94b7&reportId=6a4603a2-d1d1-47b7-9898-3575ed3758c6

    Coverage note 1: Current Mecklenburg permit lookup did not complete.

    Coverage note 2: Supplemental imported export, 2018-01-02 through 2026-09-18. The county export exceeded its volume limit and may omit jobs. Every matching local row is included; no local 200-record cap is applied.

    Permit records returned
    4

    Permit issuance and permit status do not establish that work passed final inspection. Original descriptions and available inspection findings appear below.

    Source: Official county permit and inspection records · Retrieved: Nov 26, 2026

    Neighborhood and zoning

    Verified source
    2040 Policy Map place type
    Neighborhood 1 · Northeast Inner
    Local historic district
    None mapped
    National Register district
    None mapped
    National Park Service boundary
    None mapped
    Airport noise overlay
    None mapped
    Yard Waste day
    Monday
    Garbage day
    Monday
    Recycling day
    Monday (Green week)
    Private well records
    No private-well records returned in this source.
    Census tract 37119001200 · ACS 2020-2024
    MeasureEstimate90% margin
    Median household income$83,893± $19,135
    Median owner-occupied home value$625,000± $89,203
    Median monthly gross rent$1,426/mo± $176
    Housing units2,371± 226
    Occupied housing units2,104± 254
    Owner-occupied units1,056± 143
    Renter-occupied units1,048± 252
    Median year structure built1,966± 4

    Census figures describe the surrounding tract, not this home or its occupants.

    Source: US Census Bureau ACS 5-year (tract), Charlotte Planning, NC HPO, Mecklenburg Solid Waste · Retrieved: Sep 20, 2026

    Local housing market · ZIP 28205

    Verified source
    Active listings
    436 (+31.7% vs Aug 17, 2026)
    Median asking price
    $575,000 (-2.5% vs Aug 17, 2026)
    Median asking price per sq ft
    $348 (-0.6% vs Aug 17, 2026)
    Share of listings with a price reduction
    28%
    This listing, asking price per sq ft
    $380
    Median asking price, Aug 12, 2026 to Sep 14, 2026 ($560,000 – $615,000)

    Figures describe active listings (asking prices) in this ZIP, not closed sales.

    Source: Canopy MLS via IDX Broker (Helen Harp market cache) · Information date: Sep 14, 2026 · Retrieved: Sep 21, 2026

    Public records and resources

    Verified source

    These are official public portals. Searches there are free; some documents carry the county copy fee.

    Source: Official county, state and federal record portals

    Compiled Nov 26, 2026 from the listing brokerage (via the MLS) and the official public records named in each section. Not an appraisal, survey, title search, flood determination or inspection. Owner names and mailing addresses are intentionally left out.

    Schools & Neighborhood

    Assignments depend on the exact address and can change by school year. Confirm with the school district before relying on them.

    Confirmed Attendance assignments for this address

    • Elementary · 2026-27

      Shamrock Gardens Elementary

      Grades Pre-K–5 · Public magnet · 0.7 mi

      3301 Country Club Drive, Charlotte, NC 28205

      Charlotte-Mecklenburg Schools via Mecklenburg County GIS · CMS school assignment by parcel (county GeoPortal locator) · checked 2026-11-26 · Check with the district

    • Middle · 2026-27

      Eastway Middle

      Grades 6–8 · Public magnet · 1.4 mi

      1501 Norland Rd, Charlotte, NC 28205

      Charlotte-Mecklenburg Schools via Mecklenburg County GIS · CMS school assignment by parcel (county GeoPortal locator) · checked 2026-11-26 · Check with the district

    • High · 2026-27

      Garinger High School

      Grades 9–12 · Traditional public · 0.8 mi

      1100 Eastway Dr, Charlotte, NC 28205

      Charlotte-Mecklenburg Schools via Mecklenburg County GIS · CMS school assignment by parcel (county GeoPortal locator) · checked 2026-11-26 · Check with the district

    Nearby Schools near this property

    Nearby schools are listed by straight-line distance within 5 miles. The closest school is not necessarily the assigned school.

    Show school levels

    Elementary

    • Shamrock Gardens Elementary

      0.7 mi · Grades Pre-K–5 · Public magnet

      3301 Country Club Drive, Charlotte, NC 28205

    • Merry Oaks International Academy

      0.9 mi · Grades Pre-K–5 · Traditional public

      3508 Draper Ave, Charlotte, NC 28205

    • Windsor Park Elementary

      1.1 mi · Grades Pre-K–5 · Traditional public

      3910 Sudbury Rd, Charlotte, NC 28205

    • KIPP Charlotte

      1.5 mi · Grades K–8 · Public charter

      931 Wilann Dr, Charlotte, NC 28215

    • Briarwood Academy

      1.7 mi · Grades Pre-K–5 · Traditional public

      1001 Wilann Dr, Charlotte, NC 28215

    • Winterfield Elementary

      1.7 mi · Grades Pre-K–5 · Traditional public

      3100 Winterfield Pl, Charlotte, NC 28205

    Middle

    • Eastway Middle

      1.4 mi · Grades 6–8 · Public magnet

      1501 Norland Rd, Charlotte, NC 28205

    • KIPP Charlotte

      1.5 mi · Grades K–8 · Public charter

      931 Wilann Dr, Charlotte, NC 28215

    • Highland Mill Montessori

      1.8 mi · Grades Pre-K–6 · Public magnet

      3201 Clemson Ave, Charlotte, NC 28205

    • Cochrane Collegiate Academy

      1.9 mi · Grades 6–12 · Traditional public

      6200 Starhaven Dr, Charlotte, NC 28215

    • Chantilly Montessori

      2.1 mi · Grades Pre-K–6 · Public magnet

      701 Briar Creek Rd, Charlotte, NC 28205

    • Charlotte East Language Academy

      2.2 mi · Grades K–8 · Public magnet

      6108 Wilora Lake Rd, Charlotte, NC 28212

    High

    • Garinger High School

      0.8 mi · Grades 9–12 · Traditional public

      1100 Eastway Dr, Charlotte, NC 28205

    • Commonwealth High

      1.8 mi · Grades 9–12 · Public charter

      5112 Central Ave, Charlotte, NC 28205

    • Cochrane Collegiate Academy

      1.9 mi · Grades 6–12 · Traditional public

      6200 Starhaven Dr, Charlotte, NC 28215

    • Hawthorne Academy of Health Sciences

      2.1 mi · Grades 9–12 · Public magnet

      1411 Hawthorne Ln, Charlotte, NC 28205

    • Military and Global Leadership

      2.1 mi · Grades 9–12 · Public magnet

      1411 Hawthorne Lane Ste A, Charlotte, NC 28205

    • Sugar Creek Charter

      2.3 mi · Grades K–12 · Public charter

      4101 N Tryon Street, Charlotte, NC 28206

    Not verified Information not currently verified

    • Nothing outstanding for this address.

    Public schools only (traditional, magnet and charter). Charter and magnet schools are not automatic assignments. Private schools are not included. Directory as of 2026-10-25. Property location: Mecklenburg County master address points.

    Free · no sign-up

    Flood & environmental risk

    1908 KILBORNE DR CHARLOTTE NC 28205 · Mecklenburg County, NC · parcel 09314138

    The parcel is mapped outside FEMA high-risk and moderate flood zones (Zone X, minimal hazard).

    Federal rules do not require flood insurance for this designation; it remains optional. FEMA map panel effective 2014-02-19.

    Source
    FEMA National Flood Hazard Layer
    Map effective
    2014-02-19
    Looked up
    Nov 24, 2026 02:02 UTC
    100 ftN ↑
    Parcel outline (county GIS) with FEMA flood zones drawn from the official shapes. High-risk (1%) Floodway Moderate (0.2%) / future Preliminary North is up.

    1 Mapped flood designation

    What FEMA's official map labels the land. It decides flood-insurance rules and building permits, but it is a map, not a measurement of any building.

    • Minimal flood hazard — Zone X — Outside the mapped 0.2% annual-chance floodplain. Flooding can still happen here.

    2 Parcel intersection

    Whether any part of the lot's county-mapped boundary falls inside a zone, computed from the actual shapes — not from a single centre point.

    ZoneLand inside zone
    Minimal flood hazard — Zone XIntersects (area not computed for minimal-hazard areas)

    Parcel area 9,657 sq ft · high-risk share 0%. Mapped overlap is calculated from county and FEMA map lines.

    3 Building-level exposure

    Not confirmed by this report. A flood zone on the lot does not mean the house is in it, and a house outside the zone can still flood. Confirming it takes an Elevation Certificate from a licensed surveyor, or a FEMA letter (LOMA) for the structure.

    Federally backed mortgages require flood insurance when the building is in a high-risk zone; the lender's flood determination decides that, not this map.