- Permit details
- Permit number: B4676478
Project number: NR0913360
Work category: Building permit / One/Two Family
Recorded status: Complete
Reported project value: $39,100
- Original job description and scope
- Repair/Replace. Like for like replacement(Siding/Window/Door).
- Recorded dates
- Applied: 07/30/2024 12:15 pm
Issued: 07/30/2024 12:00 am
- Inspection 1
- Inspection Id: 4676478002
Type: FR - Framing
Date: Oct 31, 2024
Status: Passed
Result: Passed
Inspector: Brown, Mark Eric
Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=663429623
Formatted Address: 5517 BROOK FALLS CT CHARLOTTE
Tax Jurisdiction: CHARLOTTE
Received Date: Oct 29, 2024
Scheduled Start Date: Oct 30, 2024
Fee Amount: $0.00
Web Source Of Request: WEB
OTIExtension Fee: $0.00
Inspection Task Results 1 / Task Performed: FR - Framing
Inspection Task Results 1 / Result: 01 - Passed
Inspection Task Results 1 / Count As Failure: 0
Inspection Task Results 2 / Confirmation Number: 4676478002
Inspection Task Results 2 / Received Date: Oct 29, 2024
Inspection Task Results 2 / Requested Date: Oct 30, 2024
Inspection Task Results 2 / Result Date: Oct 31, 2024
Inspection Task Results 2 / Overall Result: Passed
Inspection Task Results 2 / Inspector: Brown, Mark Eric
Inspection Task Results 2 / Task Performed: FR - Framing
Inspection Task Results 2 / Result: 01 - Passed
Inspection Task Results 2 / Defect Results: Task
Defect Code
Defect Description
Defect Note
- Inspection 2
- Inspection Id: 4676478003
Type: IN - Insulation
Date: Nov 13, 2024
Status: Failed
Result: Failed
Inspector: Brown, John
Comments: IN - Insulation:
Missing insulation where band insulation was removed and at garage kitchen wall
Garage is not considered apart of thermal envelope
Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=663875138
Formatted Address: 5517 BROOK FALLS CT CHARLOTTE
Tax Jurisdiction: CHARLOTTE
Received Date: Nov 12, 2024
Scheduled Start Date: Nov 13, 2024
Fee Amount: $0.00
Web Source Of Request: WEB
OTIExtension Fee: $0.00
Inspection Task Results 1 / Task Performed: IN - Insulation
Inspection Task Results 1 / Result: 02 - Failed
Inspection Task Results 1 / Chargeable Failure: Yes
Inspection Task Results 1 / Count As Failure: 1
Inspection Task Results 2 / Confirmation Number: 4676478003
Inspection Task Results 2 / Received Date: Nov 12, 2024
Inspection Task Results 2 / Requested Date: Nov 13, 2024
Inspection Task Results 2 / Result Date: Nov 13, 2024
Inspection Task Results 2 / Overall Result: Failed
Inspection Task Results 2 / Inspector: Brown, John
Inspection Task Results 2 / Task Performed: IN - Insulation
Inspection Task Results 2 / Result: 02 - Failed
Inspection Task Results 3 / Task: IN
Inspection Task Results 3 / Defect Code: 121
Inspection Task Results 3 / Defect Description: Insulation missing/Voids
- Inspection 3
- Inspection Id: 4676478001
Type: FR - Framing
Date: Oct 21, 2024
Status: Failed
Result: Failed
Inspector: Brown, John
Comments: FR - Framing:
Need information on what appears to be a floor truss repair at kitchen
Provide roof truss drawings and a clean roof truss layout
Missing house wrap at rear of existing
Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=662992599
Formatted Address: 5517 BROOK FALLS CT CHARLOTTE
Tax Jurisdiction: CHARLOTTE
Received Date: Oct 16, 2024
Scheduled Start Date: Oct 18, 2024
Fee Amount: $0.00
Web Source Of Request: WEB
OTIExtension Fee: $0.00
Inspection Task Results 1 / Task Performed: FR - Framing
Inspection Task Results 1 / Result: 02 - Failed
Inspection Task Results 1 / Chargeable Failure: Yes
Inspection Task Results 1 / Count As Failure: 1
Inspection Task Results 2 / Confirmation Number: 4676478001
Inspection Task Results 2 / Received Date: Oct 16, 2024
Inspection Task Results 2 / Requested Date: Oct 18, 2024
Inspection Task Results 2 / Result Date: Oct 21, 2024
Inspection Task Results 2 / Overall Result: Failed
Inspection Task Results 2 / Inspector: Brown, John
Inspection Task Results 2 / Task Performed: FR - Framing
Inspection Task Results 2 / Result: 02 - Failed
Inspection Task Results 3 / Task: FR
Inspection Task Results 3 / Defect Code: 177
Inspection Task Results 3 / Defect Description: Design document/letter required
- Inspection 4
- Inspection Id: 4676478004
Type: IN - Insulation
Date: Nov 15, 2024
Status: Failed
Result: Failed
Inspector: Goins, Brian K.
Comments: IN - Insulation:
Still need to insulate garage kitchen wall where insulation is missing and replace damaged wall stud at water heater location in garage. Also need to dry in roof at B vent above this location.
Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=663979127
Formatted Address: 5517 BROOK FALLS CT CHARLOTTE
Tax Jurisdiction: CHARLOTTE
Received Date: Nov 14, 2024
Scheduled Start Date: Nov 15, 2024
Fee Amount: $0.00
Web Source Of Request: WEB
OTIExtension Fee: $0.00
Inspection Task Results 1 / Task Performed: IN - Insulation
Inspection Task Results 1 / Result: 02 - Failed
Inspection Task Results 1 / Chargeable Failure: Yes
Inspection Task Results 1 / Count As Failure: 1
Inspection Task Results 2 / Confirmation Number: 4676478004
Inspection Task Results 2 / Received Date: Nov 14, 2024
Inspection Task Results 2 / Requested Date: Nov 15, 2024
Inspection Task Results 2 / Result Date: Nov 15, 2024
Inspection Task Results 2 / Overall Result: Failed
Inspection Task Results 2 / Inspector: Goins, Brian K.
Inspection Task Results 2 / Task Performed: IN - Insulation
Inspection Task Results 2 / Result: 02 - Failed
Inspection Task Results 3 / Task: IN
Inspection Task Results 3 / Defect Code: A12
Inspection Task Results 3 / Defect Description: Previous defects not corrected/Unresolved
Inspection Task Results 3 / Defect Note: Defect items identified in a previous inspection have not been completed by the contractor and remain unresolved. Recommending contractor review site, resolve issues, and reschedule when ready.
Inspection Task Results 4 / Task: IN
Inspection Task Results 4 / Defect Code: A9
Inspection Task Results 4 / Defect Description: No specific defect item applies
Inspection Task Results 4 / Defect Note: No specific defect item applies from published listing: inspector must enter appropriate notes to identify item.
- Inspection 5
- Inspection Id: 4676478005
Type: IN - Insulation
Date: Nov 27, 2024
Status: Passed
Result: Passed
Inspector: Brown, John
Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=664342180
Formatted Address: 5517 BROOK FALLS CT CHARLOTTE
Tax Jurisdiction: CHARLOTTE
Received Date: Nov 26, 2024
Scheduled Start Date: Nov 27, 2024
Fee Amount: $0.00
Web Source Of Request: WEB
OTIExtension Fee: $0.00
Inspection Task Results 1 / Task Performed: IN - Insulation
Inspection Task Results 1 / Result: 01 - Passed
Inspection Task Results 1 / Count As Failure: 0
Inspection Task Results 2 / Confirmation Number: 4676478005
Inspection Task Results 2 / Received Date: Nov 26, 2024
Inspection Task Results 2 / Requested Date: Nov 27, 2024
Inspection Task Results 2 / Result Date: Nov 27, 2024
Inspection Task Results 2 / Overall Result: Passed
Inspection Task Results 2 / Inspector: Brown, John
Inspection Task Results 2 / Task Performed: IN - Insulation
Inspection Task Results 2 / Result: 01 - Passed
Inspection Task Results 2 / Defect Results: Task
Defect Code
Defect Description
Defect Note
- Inspection 6
- Inspection Id: 4676478007
Type: FI - Final Inspection
Date: Jan 30, 2025
Status: Passed
Result: Passed
Inspector: Ozuna, Seferino
Comments: FI - Final Inspection:
Previous defects corrected
Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=666181207
Formatted Address: 5517 BROOK FALLS CT CHARLOTTE
Tax Jurisdiction: CHARLOTTE
Received Date: Jan 29, 2025
Scheduled Start Date: Jan 30, 2025
Fee Amount: $0.00
Web Source Of Request: WEB
OTIExtension Fee: $0.00
Inspection Task Results 1 / Task Performed: FI - Final Inspection
Inspection Task Results 1 / Result: 01 - Passed
Inspection Task Results 1 / Count As Failure: 0
Inspection Task Results 2 / Confirmation Number: 4676478007
Inspection Task Results 2 / Received Date: Jan 29, 2025
Inspection Task Results 2 / Requested Date: Jan 30, 2025
Inspection Task Results 2 / Result Date: Jan 30, 2025
Inspection Task Results 2 / Overall Result: Passed
Inspection Task Results 2 / Inspector: Ozuna, Seferino
Inspection Task Results 2 / Task Performed: FI - Final Inspection
Inspection Task Results 2 / Result: 01 - Passed
Inspection Task Results 2 / Defect Results: Task
Defect Code
Defect Description
Defect Note
- Inspection 7
- Inspection Id: 4676478006
Type: FI - Final Inspection
Date: Jan 28, 2025
Status: Failed
Result: Failed
Inspector: Brown, John
Comments: FI - Final Inspection:
Install smoke alarms at master bedroom
Seal vent in garage ceiling
Source Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=BuildingRequestsDetailpublicVi&PosseObjectId=666024420
Formatted Address: 5517 BROOK FALLS CT CHARLOTTE
Tax Jurisdiction: CHARLOTTE
Received Date: Jan 24, 2025
Scheduled Start Date: Jan 27, 2025
Fee Amount: $0.00
Web Source Of Request: WEB
OTIExtension Fee: $0.00
Inspection Task Results 1 / Task Performed: FI - Final Inspection
Inspection Task Results 1 / Result: 02 - Failed
Inspection Task Results 1 / Chargeable Failure: Yes
Inspection Task Results 1 / Count As Failure: 1
Inspection Task Results 2 / Confirmation Number: 4676478006
Inspection Task Results 2 / Received Date: Jan 24, 2025
Inspection Task Results 2 / Requested Date: Jan 27, 2025
Inspection Task Results 2 / Result Date: Jan 28, 2025
Inspection Task Results 2 / Overall Result: Failed
Inspection Task Results 2 / Inspector: Brown, John
Inspection Task Results 2 / Task Performed: FI - Final Inspection
Inspection Task Results 2 / Result: 02 - Failed
Inspection Task Results 3 / Task: FI
Inspection Task Results 3 / Defect Code: 109
Inspection Task Results 3 / Defect Description: Garage separation
Inspection Task Results 4 / Task: FI
Inspection Task Results 4 / Defect Code: 178
Inspection Task Results 4 / Defect Description: Smoke/CO detector installation
- Contractor 1
- Role: Building
Name: EMERGENCY RESTR EXPERTS LLC
License: 74174
- Document 1
- Title: Permit Document
Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=660352919
- Document 2
- Title: Recap Report
Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=667403522
- Document 3
- Title: View Certificate of Compliance
Url: https://webpermit.mecklenburgcountync.gov/download.aspx?PosseObjectId=666204231
- Related record 1
- Project Number: NR0913360
Title: 24-CLT-0649-PSTR-[personal information omitted] Repair/Replace. Like for like replacem
Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=Project&PosseObjectId=660352891
Relationship: County Project
- Related record 2
- Permit Number: E4676497
Project Number: NR0913360
Title: Electrical permit
Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=ElectricalPermit&PosseObjectId=660352902
Relationship: Linked County Record
- Related record 3
- Permit Number: M4676496
Project Number: NR0913360
Title: Mechanical permit
Url: https://webpermit.mecklenburgcountync.gov/Default.aspx?PossePresentation=MechanicalPermit&PosseObjectId=660352895
Relationship: Linked County Record
- Additional Permit Details
- Inspection Results: Inspection Results
Permit Document: Permit Document
Certificate Of Occupancy: Recap Report
View Certificate Of Compliance: View Certificate of Compliance
Project Address: 5517 BROOK FALLS CT
Parcel Number: 04307450
Lot: 12
Tax Jurisdiction: CHARLOTTE
Project Phase: Closed
Job Location: interior and exterior
Front Setback: 41.0
Left Setback: 6.0
Right Setback: 6.0
Rear Setback: 40.0
Property Use: Residential - One/Two Family
USDCCode: 434 - Res Dwelling (Alteration, Repair, Replace)
Occupancy: R3 * RESIDENTIAL - SINGLE FAMILY
Construction Type: 5B * WOOD FRAME/UNPROTECTED
Number Of Units: 1
Exterior Work: Yes
Number Of Rooms: 9
Number Of Bedrooms: 3
Number Of Baths: 3.0
Building Contract Cost: $30,000
Sub Permits Contract Cost: $9,100
Total Of All Equipment: $0.00
Equipment Costat100: $0.00
Cost At20Percent: $0.00
Total Equip Fee: $0.00
Building Conrtractor Contr ID: X49062 EMERGENCY RESTR EXPERTS LLC
Electrical Service: Existing
Electric Utility Company: Duke Energy
Mechanical Utility Company: PIEDMONT NATURAL GAS
Utilities: Existing
Public Util Indiv Meter Conn Water: Yes
Public Util Master Meter Conn Water: Yes
Public Util Indiv Meter Conn Sewer: Yes
Public Util Master Meter Conn Sewer: Yes
Permit Fee Type: Construction
Permit Fee: $510.73
Triple Permit Fee Penalty: $0.00
NESHAPFee: $0.00
Fire Damage Surcharge: $0.00
Fee Adjustment: $0.00
Tech Surcharge: $2.00
Total Fee: $512.73
Fast Track Fee: $0.00
Commercial Surcharge Fee: $0.00
Created By User Name: EMERGENCY RES. EXPERTS LLC
Issued By: EMERGENCY RES. EXPERTS LLC
- Project Details
- 1 / Web Project Address: 5517 BROOK FALLS CT
1 / Parcel Number: 04307450
1 / Lot: 12
1 / Tax Jurisdiction: CHARLOTTE
1 / Project Status: Closed
1 / Building Permits Issued: 1
1 / Building Permits Required: 1
1 / Electrical Permits Issued: 1
1 / Electrical Permits Required: 1
1 / Mechanical Permits Issued: 1
1 / Mechanical Permits Required: 1
1 / Plumbing Permits Issued: 1
1 / Plumbing Permits Required: 1
1 / Zoning Permits Issued: 0
1 / Zoning Use Permits Required: 0
1 / Other Permits Issued: 0
1 / Other Permits Required: 0
1 / Total Issued Permits: 4
1 / Total Required Permits: 4
1 / TCODisplay Date: Not Issued
1 / Certificate Of Occupancy Type: Not Issued
1 / Is Gas Utility Type: Yes
1 / Is Electrical Utility Type: Yes
1 / Utility Date: Mar 13, 2025
1 / RTAPs: RTAP Number
Closed
RTAP Level
Permit Number
RTAP for Project Number
Base Project Number
Inspector
Inspector Number
Comments
- Permit Remarks
- 1 / Title: Permit Remarks
1 / Text: Tree fell on home. Roof, drywall electrical and mechanical repairs are needed
recharging ac system, replace central air, replace air handler
electrical is replacing the 200 amp
1 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=660352890
2 / Title: Permit Remarks
2 / Text: HVAC equipment may encroach into set-back area by 50%.
2 / Source Url: https://webpermit.mecklenburgcountync.gov/Note.aspx?Title=Permit+Remarks&PosseObjectId=660352915
- Additional Public Detail Rows
- 1 / External File Num: E4676497
1 / Issue Date: Jul 30, 2024
1 / Trade Type: E - Electrical
1 / Status Description: Complete
2 / External File Num: M4676496
2 / Issue Date: Jul 30, 2024
2 / Trade Type: M - Mechanical
2 / Status Description: Complete
3 / External File Num: R4767127
3 / Issue Date: Jan 24, 2025
3 / Trade Type: Hold
3 / Status Description: Closed
4 / External File Num: R4767128
4 / Issue Date: Jan 24, 2025
4 / Trade Type: Hold
4 / Status Description: Closed
5 / Last Update By User Name: EMERGENCY RES. EXPERTS LLC
5 / Last Update Date: Jul 30, 2024
- Record source